For the protection and longevity of equipments of your pool, it is imperative to respect literally the instructions of use
mentioned in this manual. The presence of an amperometric chlorine regulation, of a redox production controller or a
pH regulation do not exempt from the strict respect of the instructions and do not have authority to eliminate the risks
and damages but only to limit them. Indeed, in spite of the smooth running of a control or regulation device, other
factors may cause damage, in particular :
- an insufficient ventilation in case of covered pool (shelter, tarpaulin, cover)
- a maintenance default of analysis probes (calibration, addition of the consumable...)
- manual processing of supplements excessive or not adapted (choc processing...)
- the non compliance with the instructions of use described in the present user manual
These isolated or organized factors will tend to cause oxidation on all metallic parts and of automatic cover pins and
slats, telescopic shelters and heat exchangers can lead to irreversible deterioration (discoloration) of the pool lining.
Therefore, if the manufacturer's responsibility was engaged for a malfunction of the control or regulation device, it
would be limited to the repair or the replacement of the product free of charge. Then, it is strongly recommended to
check the levels of chlorine and pH each week with your usual analysis kit.

6/ MAINTENANCE

WINTERIZING
1
In case of pool winterizing (draining and/or stop of the filtration), achieve the following operations:
 Remove the pH or ORP probe (According to model) from saddle.
 Keep it in his original protection filled with city water (or in a glass), in a place where it will not freeze
during winter.
 Instead of the probe, use the supplied cork.
Rinse the flexible pipes of peristaltic pumps with clean water. Using the function "MA" and clean water
can. Turn off the device.
2
RESTARTING
2
e
a- Consumable changes
ct
ur
e
Santoprene tubing
d
u
p
H
p
ar
di
o
d
 For each pump, change the pump body tube. Beforehand, it has to be coated of silicon grease. Use of
e
chlorine liquid tin is useful, several times each season.
1
 To each injection connector, take off it and replace the valve anti-return valve.