6
Option: MEASURING CHAMBER
Install the first saddle. Mark then drill the pipe. With some Teflon, mount the little valves on the saddle
and the the injection connector on the little valves.
Install the second saddle. Mark then drill the pipe. With some Teflon, assemble the little valve in the
same way, and then the injection connector on the second saddle.
Connect one part of the tube between connectors and measuring chamber.
Remove the rubber protection from each probe and mount it on the probe-holder corresponding.
Connect the cable of each probe (BNC jack) on the base of the controller box.
4/ PARAMETERS SETTING
CONTROL PANEL
1
Navigation and choosing
Cancellation
Long press: On/Off
Short press: back
To reach the control menu: press 3 seconds on the key
Select the function code using the keys
Select the wished value with the keys
The value is frozen and the device returns to the previous menu.
JUSTDOSING UNO - DUO - REDOX - DUO REDOX - PAPI004051MULTI1 - FR/EN/ES/DE - Rev.05.16
Display of
values in live
V
then confirm by
and then valid by
V
Long press: Menu access
Short press: validation
to reach the value.
V
to record the value.
10