PH PROBE AND INJECTION SYSTEM
1/ Connect the suction strainer to the entry of the pH pump with a part of the supplied pipe. Respect the
sense of arrows representing on the top of the pH pump.
2/ Install with some Teflon and hand screw the injection connector on the first saddle. Connect the exit of
the Ph pump to the injection connector with the rest of the supplied pipe (respect the sense of arrows).
3/ Install with some Teflon the probe-holder on the second saddle. Remove the rubber protection at the end
of the pH probe. Push the probe in the probe-holder (make sure that it is not in abutment with the
waterworks).
4/ Connect the cable of the pH probe (BNC jack) under the controller box.
Note : The probe must be installed vertically on the saddle. A different assembly will damage the precision of the probe
measure (can make it non efficiency).
JUSTDOSING UNO - DUO - REDOX - DUO REDOX - PAPI004051MULTI1 - FR/EN/ES/DE - Rev.05.16
4/
An incorrect positioning of
the injection connector can
entail the deterioration of
the pump.