Choose the type of corrective agent (Acid by default).
Co
Allows modifying the pH corrective mode between acid or basic. The device
is parameterized to regular he acid mode (make fall the pH). You can
change in basic mode (make rise the pH).
Adjust the volume of the pool.
CP
This device has a proportional regulation to the volume of the pool. For an
optimum efficiency, calibrate the volume corresponding to your pool in the device
and to the following board :
Pool volume
0 to 1 m
1 to 2 m
2 to 3 m
3 to 4 m
4 to 5 m
5 to 6 m
6 to 7 m
7 to 8 m
8 to 9 m
9 to 10 m
Set the pH instruction (7.2 by default).
SE
Allows changing the pH value to maintain in the swimming pool.
"OF" failling Option
OP
Don't change without ask to your dealer beforehand.
ORP regulation Menu - in addition for the redox Model
Code
Start a manual injection of the redox pump.
MA
Allows correcting manually the tin and add disinfectant without
manipulate the tin.
Calibrate the redox probe.
Allows by the device to display the ORP value found in your swimming pool
Ad
with your analysis kit (Ex: on screen, display will be 47. Be equivalent to
value of 470 mV).
Set the redox instruction (by step of 10 mV).
SE
Allows setting the ORP regulation instruction. The device is already
calibrated in factory for a 780 mV ORP instruction (on screen will be
appeared 78.)
JUSTDOSING UNO - DUO - REDOX - DUO REDOX - PAPI004051MULTI1 - FR/EN/ES/DE - Rev.05.16
Code
Pool volume
3
01
10 to 15 m
3
02
15 to 20 m
3
03
20 to 25 m
3
04
25 to 30 m
3
05
30 to 35 m
3
06
35 to 40 m
3
07
40 to 45 m
3
08
45 to 50 m
3
09
50 to 55 m
3
10
55 to 60 m
Code
Pool volume
3
11
60 to 70 m
3
12
70 to80 m
3
13
80 to 90 m
3
14
90 to 100m
3
15
100 to 110m
3
16
110 to 120 m
3
17
120 to 130 m
3
18
130 to 140 m
3
19
140 to 150 m
3
20
150 to 160 m
Function
Acid (pH-) or
basic (pH+)
Code
3
21
3
22
From 1 to 160 m
3
23
3
24
3
25
3
26
3
27
3
28
3
29
3
30
From 6.8 to 7.6
ON/OFF
Setting
From 0 to 9,5 mn
From 400 to
800 mV
From 500
to 900 mV
3
13