Installation
The site of installation should be at least 50 cm
away from another light because heat radiated from
it may activate the system. To obtain the specified
max. reach of 14 m, the sensor should be installed
at a height of approx. 2 m. Install the unit on a firm
surface to avoid unintentional triggering.
The mains supply lead is a 3-core cable.
Functions
Light threshold
(response threshold)
(factory setting:
Daylight operation at 2000 lux)
2 – 2000 lux
Switch-off delay
(time setting)
(factory setting: 8 sec.)
8 sec. – 35 min.
Reach setting/adjustment
The detection zone setting can be optimised to
suit requirements. Reach 2 – 14 m.
L = phase conductor (usually black or brown)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
Important: Connecting the conductors to the wrong
terminals will produce a short circuit in the unit or
your fuse box at a later stage when you come to
switch the power on. In this case, you must identify
the individual cables and re-connect them. A suitable
mains switch for switching the light "ON" and "OFF"
can be installed in the mains lead.
Sensor response threshold can be infinitely varied
from 2 – 2000 lux.
Control dial set to
= daylight operation
approx. 2000 lux.
Control dial set to
= twilight operation approx. 2 lux.
To adjust the detection zone in daylight, the control
dial must be set to (daylight operation).
Control dial set to – = shortest time (8 sec.)
Control dial set to + = longest time (35 min.)
When setting the detection zone, we recommend
selecting the shortest time.
a) By swivelling the sensor unit through 90°and tilting
it through 180°.
b) using adhesive shrouds, e.g. to mask out paths
or neighbouring property.
- 10 -
Operation and maintenance
The unit is not suitable for burglary alarm systems as
it is not tamperproof in the manner prescribed for
such systems. Weather can affect operation of the
sensor-switched LED floodlight. Strong gusts of wind,
snow, rain and hail may cause the light to come 'ON'
Technical specifications
Dimensions (H x W x D):
210 x 175 x 180 mm
Weight:
1.3 kg
Output:
170 LED's approx. 14,8 W
Additional switching capacity: 800 W max. (resistive load, e.g. filament bulbs)
400 W max. (uncorrected, inductive, cos ϕ = 0.5, e.g. fluorescent lamps)
400 W max. (electronic ballasts, capacitive, e.g. low-energy lamp,
4 each, ≤ 88 )
LED lifespan:
up to 50,000 hrs. (at 3 hrs./day, approx. 45 years)
Detection angle:
140° with sneak-by guard
Detection reach:
14 m max.
Projected area:
307 cm
2
+ 175 cm
Sensor unit
180° (swivelling), 90° (tilting)
adjustment range:
Floodlight
180° (swivelling), 120° (tilting)
adjustment range:
Time setting:
8 sec. – 35 min.
Twilight setting:
2 – 2000 lux
IP rating:
IP 44
Protection class:
I
Temperature range:
-20° C to +40° C
when it is not wanted because the sensor is unable to
distinguish sudden changes in temperature from
sources of heat.
The detector lens may be cleaned with a damp cloth
if it gets dirty (do not use cleaning agents).