Connecting the ADN-W AM antenna module to the ADN CU1 central unit
Connecting the ADN-W AM antenna module
to the ADN CU1 central unit
To optionally combine the antenna module with wired conference
units, connect the antenna module just like a wired conference unit:
Or:
10cc|ccADN-W AM
Use a system cable (supplied with the ADN-W AM; the maximum
cable length allowed is 50 m) to connect the
9
PORT I
socket
of the ADN CU1 central unit to the input
4
socket
of the antenna module.
If the power supplied to the antenna module via the system
cable is not sufficient (the antenna module does not switch on),
you have to power the antenna module using the NT 12-50C
power supply (see page 5).
Optionally, you can also connect the antenna module to the
PORT
sockets of an ADN PS power supply. It does not matter if
you are using a string or ring topology. The antenna module is
connected just like a conference unit to the cable string or cable
ring.
ADN CU1
IN –– AUDIO –– OUT
PORT II
PORT I
100-240V~
2x 52.8V
1.75A
50/60Hz 240W
8
9
PORT II
PORT I
Use a system cable to connect the output socket
antenna module to the
conference unit.
Use a system cable to connect the
ADN C1 wired conference unit to the input socket
antenna module.
PORT II
ADN-W AM
3
4
IN
socket of an ADN D1 or ADN C1 wired
OUT
socket of an ADN D1 or
8
socket
or
3
of the
4
of the