PREPARING THE INSTALLATION OF THE DEVICE
Installation guidelines
- This device was designed to be installed in residential premises . In any
other case, please call your distributor .
- Installation must comply with the standards currently enforced in the
country of use .
- The device must be supplied with 230V single-phase 50Hz .
- In damp areas such as bathrooms and kitchens, you must install the
connection box at least 25cm above the floor.
Keep the device away from any draughts that may interfere
with its operation (e.g.: under a centrally controlled fan, etc...). Do not
install the heater under a fixed socket.
The device is fitted with a detection system, whose sensor is located
on the front of the device .
Installation
Volume 1 No electrical device
Volume 2
Comply with the minimum distances
from any furniture units when posi-
tioning the device .
Do not install a shelf above vertical
devices .
50 cm
To optimise absence detection by
your device, do not install it in a
closed off corner or behind furniture .
15 cm
Class II IPX24 electri-
cal device (EN 60335-
2-43 : 2003/A2 : 2008)
30