Make Gas Connection - Maytag MGC7630WB Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Make Gas Connection

WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Typical flexible connection
1. Apply pipe-joint compound made for use with Natural and LP
gas to the smaller thread ends of the flexible connector
adapters (see C and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
8
3. Use a ¹⁵⁄₁₆" combination wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked.
No appliance
below cooktop
Wall oven installed below cooktop
A
B
C
D
E
F
G
H
I
A. Manifold entrance
B. Gas pressure regulator
C. Use pipe-joint
compound.
D. Adapter (must have ½"
male pipe thread)
E. Flexible connector
F. Adapter
G. Use pipe-joint
compound.
G. Use pipe-joint compound.
H. Manual gas shutoff
valve
I. ½" or ¾" gas pipe
4. Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop base and in a position
where you can reach the regulator access cap.
A
A. Access cap
B. Rear of cooktop
C. Gas pressure regulator
D. Up arrow. Regulator must be installed with
arrow pointing up to cooktop bottom.
A
B
C
D
E
F
G
H
I
J
K
A. Manifold entrance
³⁄₈
B.
" elbow
C. Use pipe-joint compound.
³⁄₈
D. Adapter (must have
" male pipe
thread)
E. Flexible connector (pass through wall
between cabinets)
³⁄₈
F. Adapter (must have
" male pipe
thread)
H. Appliance pressure regulator
(supplied)
I. ½" or ¾" gas pipe
J. Manual gas shutoff valve
K. ½" or ¾" gas pipe
B
C
D