If the room temperature is lower than the required value, it is advisable to set a higher order curve and vice versa. Pro-
ceed by increasing or decreasing in steps of one and check the result in the room.
OFFSET = 20
90
85
80
70
60
50
40
30
20
20
10
A
If the Remote Timer Control (optional) is connected to the boiler, the above adjustments are managed accord-
ing to that given in table 1.
Table. 1
Heating temperature adjustment
DHW temperature adjustment
Summer/Winter changeover
Eco/Comfort selection
Sliding Temperature
36
90
85
80
70
60
50
40
30
20
20
10
fig. 14 - Compensation curves
10
9
8
7
6
5
4
3
2
1
0
-10
-20
fig. 15 - Example of parallel compensation curve shift
Adjustment can only be carried out from the Remote Timer Control menu.
Adjustment can only be carried out from the Remote Timer Control menu.
Summer mode has priority over a possible heating demand from the Remote
Timer Control.
On disabling DHW from the Remote Timer Control menu, the boiler selects
Economy mode. In this condition, selection from the boiler panel is not possi-
ble.
On enabling DHW from the Remote Timer Control menu, the boiler selects
Comfort mode. In this condition, selection from the boiler panel is possible.
Both the Remote Timer Control and the boiler card manage Sliding Tempera-
ture adjustment: the boiler card Sliding Temperature has priority.
cod. 3540G380 - 02/2007 (Rev. 00)