Dometic MS880 Instructions De Montage Et De Service page 32

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 79
Synchronising with an analogue connection
Step 4
➤ Press the accelerator pedal slowly as far as it will go and let it return the same way
slowly as far as the neutral position.
✓ A constant signal sounds during this procedure.
Step 5
When steps 1 to 4 have been successfully completed:
➤ Activate the brake.
✓ The set values are stored permanently in the electronic module.
✓ Teach mode will be exited.
12.4
Testing MagicSpeed (diagnosis mode)
The cruise control has a self-diagnosis mode. The self-diagnosis mode is divided into
three sections (modes A, B and C) and tests all components and functions of the
cruise control.
➤ Before you start self-diagnosis, check again that all the cables are correctly
connected.
➤ Apply the handbrake.
➤ Shift the gear to neutral, or to neutral or park if it is automatic.
➤ Press down the SET button on the control element and hold it.
➤ Switch on the ignition.
✓ An audible signal sounds as long as you hold the SET button.
➤ Let go of the SET button.
✓ The audible signal stops.
If you hear another signal within a second of letting go of the SET button, a
control input is activated, for example the clutch switch.
➤ Check the cable connections to find the control input.