CLEANING/MAINTENANCE
Always switch the appliance off before removing the water tank. Do not reach inside the nebuliser space
while the appliance is running!
• Switch off the appliance (17) and remove the plug from the mains socket (18) before cleaning.
• Clean the water tank and the nebuliser space regularly once a week (use only water, without
detergent) (19).
• Decalcify the water base regularly using commercially available decalcification agents (20).
Rinse out the decalcification agent thoroughly with plenty of water.
• To remove the mist outlet (21): Twist the mist outlet to either the right or the left. Align the arrow on
the mist outlet with the arrow on the ring around the mist outlet. Only one set of arrows on mist
outlet and ring will align. Pull up on the mist outlet once the arrows are aligned.
Figure 17
Figure 19
Figure 21
44
Solis_Digisonic_Betriebsanleitung.indd 44-45
Figure 18
Figure 20
IMPORTANT!
• Make sure that no water gets into the lower part of the main body (22).
• Clean the inner parts with a soft cloth. Never use any solvents or aggressive cleaning agents (23).
• Only use the brush to clean the membrane (24). This should be done once a week.
• Change the water in the tank at least once a week.
• We do not recommend the use of this SOLIS Ultrasonic Nebulizer if your water is harder than 25 fH!
In that case please check whether a SOLIS Airwasher would be more appropriate.
• Please do not use water that has been through a domestic water softener. The decalcification
cartridge in the humidifier is unable to absorb the salt it contains, which causes a white precipitate
around the unit.
Figure 22
Figure 24
Figure 23