REFILLING THE WATER TANK DURING OPERATION
An indicator light will tell you when there is no more water in the cleaner (E-fig.2)
If this happens the boiler stops heating automatically.
WHAT TO DO
- Switch off the boiler heating switch.
- Continue working to use up any remaining steam in the boiler. If this is not done, you
will not be able to open the self-locking filler cap.
- Switch off the main switch.
- Remove the plug from a socket.
- With a towel to protect your hand carefully unscrew the self-locking cap and let any
remaining steam escape
- Remove the safety cap.
- Fill the tank with water as described in section "Setting up/How to fill the boiler"(page-9).
- Re-connect the appliance and start up as described in section "How to start up" (page-10).
MAINTENANCE
DESCALING (Fig. 14)
(every 3-4 weeks)
ATTENTION:
Never descale
the appliance
when still
warm.
-
Unplug.
-
Fill the tank with tap water.
Do not add anything other
than simple tap water
-
Hold the appliance
upright and shake
thoroughly to loosen any
scale in the boiler chamber.
-
Open the drain at the bottom of the boiler (14) using the key on the safety cap.
-
Collect the water coming from the boiler.
-
Rinse the repeatedly with tap water (ONLY TAP WATER) until there are no
further traces of scaling.
-
Close the drain at the bottom of the boiler (14).
CLEANING THE APPLIANCE
Clean the appliance and accessories with a damp cloth. Never use steam or immerse in
water.
Fig. 14