Contents
1. Safety precautions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
. Installation location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
3. Installing the outdoor unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4. Installing the refrigerant piping. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
5. Drainage piping work. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Note: This symbol mark is for EU countries only.
This symbol mark is according to the directive 2002/96/EC Article 10 Information for users and Annex IV.
Your MITSUBISHI ELECTRIC product is designed and manufactured with high quality materials and components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste.
Please, dispose of this equipment at your local community waste collection/recycling centre.
In the European Union there are separate collection systems for used electrical and electronic product.
Please, help us to conserve the environment we live in!
Caution:
• Do not vent R410A into the Atmosphere:
• R410A is a Fluorinated Greenhouse gas, covered by the Kyoto Protocol, with a Global Warming Potential (GWP)=1975.
1. Safety precautions
► B efore installing the unit, make sure you read all the "Safety precautions".
► P lease report to or take consent by the supply authority before connec-
tion to the system.
► Equipment complying with IEC/EN 61000-3-12
(PUHZ-RP100/125/140VKA)
► PUHZ-RP200/250Y
"This equipment complies with IEC 61000-3-12 provided that the short-
circuit power S
is greater than or equal to S
sc
between the user's supply and the public system. It is the responsibility
of the installer or user of the equipment to ensure, by consulation with
the distribution network operator if necessary, that the equipment is
connected only to a supply with a short-circuit power S
equal to S
(*1)"
sc
S
(*1)
sc
Model
PUHZ-RP00Y
PUHZ-RP50Y
Warning:
• T he unit must not be installed by the user. Ask a dealer or an authorized
technician to install the unit. If the unit is installed incorrectly, water leak-
age, electric shock, or fire may result.
• F or installation work, follow the instructions in the Installation Manual and
use tools and pipe components specifically made for use with R410A re-
frigerant. The R410A refrigerant in the HFC system is pressurized 1.6 times
the pressure of usual refrigerants. If pipe components not designed for
R410A refrigerant are used and the unit is not installed correctly, the pipes
may burst and cause damage or injuries. In addition, water leakage, elec-
tric shock, or fire may result.
• T he unit must be installed according to the instructions in order to mini-
mize the risk of damage from earthquakes, typhoons, or strong winds. An
incorrectly installed unit may fall down and cause damage or injuries.
• T he unit must be securely installed on a structure that can sustain its
weight. If the unit is mounted on an unstable structure, it may fall down
and cause damage or injuries.
• I f the heat pump unit is installed in a small room, measures must be taken
to prevent the refrigerant concentration in the room from exceeding the
safety limit in the event of refrigerant leakage. Consult a dealer regarding
the appropriate measures to prevent the allowable concentration from be-
ing exceeded. Should the refrigerant leak and cause the concentration limit
to be exceeded, hazards due to lack of oxygen in the room may result.
• V entilate the room if refrigerant leaks during operation. If refrigerant comes
into contact with a flame, poisonous gases will be released.
• A ll electric work must be performed by a qualified technician according to
local regulations and the instructions given in this manual. The units must
be powered by dedicated power lines and the correct voltage and circuit
breakers must be used. Power lines with insufficient capacity or incorrect
electrical work may result in electric shock or fire.
1.1. Before installation
Caution:
• D o not use the unit in an unusual environment. If the heat pump unit is
installed in areas exposed to steam, volatile oil (including machine oil), or
sulfuric gas, areas exposed to high salt content such as the seaside, or
areas where the unit will be covered by snow, the performance can be sig-
nificantly reduced and the internal parts can be damaged.
• D o not install the unit where combustible gases may leak, be produced,
flow, or accumulate. If combustible gas accumulates around the unit, fire
or explosion may result.

6. Electrical work . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7. Test run . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
9. Special Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
10. System control (Fig. 10-1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Describes precautions that must be observed to prevent danger of injury or
death to the user.
Describes precautions that must be observed to prevent damage to the unit.
After installation work has been completed, explain the "Safety Precautions," use,
(*1) at the interface point
sc
and maintenance of the unit to the customer according to the information in the
Operation Manual and perform the test run to ensure normal operation. Both the
Installation Manual and Operation Manual must be given to the user for keeping.
These manuals must be passed on to subsequent users.
greater than or
sc
S
(MVA)
sc
1.35
Carefully read the labels affixed to the main unit.
1.49
• U se C1220 copper phosphorus, for copper and copper alloy seamless
• U se only specified cables for wiring. The wiring connections must be made
Failure to observe these instructions may result in overheating or a fire.
• T he terminal block cover panel of the outdoor unit must be firmly attached.
• W hen installing or relocating, or servicing the heat pump unit, use only the
T he use of any refrigerant other than that specified for the system will cause
• U se only accessories authorized by Mitsubishi Electric and ask a dealer
• D o not alter the unit. Consult a dealer for repairs. If alterations or repairs are
• T he user should never attempt to repair the unit or transfer it to another
• A fter installation has been completed, check for refrigerant leaks. If refrig-
• The outdoor unit produces condensation during the heating operation.
• W hen installing the unit in a hospital or communications office, be pre-
Warning:
Caution:
: Indicates a part which must be grounded.
Warning:
pipes, to connect the refrigerant pipes. If the pipes are not connected cor-
rectly, the unit will not be properly grounded and electric shock may result.
securely with no tension applied on the terminal connections. Also, never
splice the cables for wiring (unless otherwise indicated in this document).
If the cover panel is mounted incorrectly and dust and moisture enter the
unit, electric shock or fire may result.
specified refrigerant (R410A) to charge the refrigerant lines. Do not mix it
with any other refrigerant and do not allow air to remain in the lines.
I f air is mixed with the refrigerant, then it can be the cause of abnormal high pres-
sure in the refrigerant line, and may result in an explosion and other hazards.
mechanical failure or system malfunction or unit breakdown. In the worst
case, this could lead to a serious impediment to securing product safety.
or an authorized technician to install them. If accessories are incorrectly
installed, water leakage, electric shock, or fire may result.
not performed correctly, water leakage, electric shock, or fire may result.
location. If the unit is installed incorrectly, water leakage, electric shock,
or fire may result. If the heat pump unit must be repaired or moved, ask a
dealer or an authorized technician.
erant leaks into the room and comes into contact with the flame of a heater
or portable cooking range, poisonous gases will be released.
Make sure to provide drainage around the outdoor unit if such condensa-
tion is likely to cause damage.
pared for noise and electronic interference. Inverters, home appliances,
high-frequency medical equipment, and radio communications equipment
can cause the heat pump unit to malfunction or breakdown. The heat pump
unit may also affect medical equipment, disturbing medical care, and com-
munications equipment, harming the screen display quality.