2.3) Oil release
By operating the pressure release button (2), the ram of the con-
nected head retracts and the oil returns to the reservoir.
IMPORTANT: Before disconnecting the fl exible hose, hold
the release button (2) depressed until the ram of the head
is fully retracted.
2.4) LED Worklights
While the pump is in operation, two high luminosity LED worklights switch on and switch off au-
tomatically at the end of the cycle.
2.5) Battery status
The battery is equipped with LED indicators that indicate the
remaining battery life at any time by pressing the adjacent
button (P):
4 LEDs illuminated: fully charged
2 LEDs illuminated: 50 % capacity
1 LED flashing: minimum charge, replace the battery
Worklights illuminated combined with an alarm audible when the operating button (1) is
pressed, indicate that the battery voltage has dropped below a minimum safety threshold;
under these conditions the tool will not start, and it is necessary to recharge or replace the
battery.
The approximate time to fully recharge a battery is about 80 minutes.
After each working cycle, and after the extraction of the battery from the pump, an inte-
grated battery cut-off device will operate after 70 s approx.
Then the LED nearest to button (P) will fl ash 5 times every 14 s approx. The battery will be
reactivated when it is reintroduced into the pump and the operating button is pressed.
2.6) Using the battery charger
Carefully follow the instructions in the battery charger user manual.
3. MAINTENANCE
The pump is robust, completely sealed, and requires very little daily maintenance. Compliance with
the following points, should help to maintain its optimum performance:
3.1) Thorough cleaning
Dust, sand and dirt are a danger for any hydraulic device.
Every day, after use, the pump must be wiped with a clean cloth taking care to remove any residue.
Do not use Hydrocarbons to clean the rubber parts.