Thorough Cleaning - Cembre B68M-P18 Notice D'utilisation Et Entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

4.7) Errors/Malfunctions
These appear on the display during operation, combined with a beep to notify the operator of
procedural or operational errors.
Message
In CRIMPING mode, oil discharge is
ERROR
activated before waiting for the mo-
tor to be automatically switched off
Interruption of the signal from
NTC
the NTC temperature probe of the
FAULT
battery.
The pump has been started without
fl exible hose connected or the fl e-
xible hose is not correctly connected
Abnormal power consumption of
the motor.
001
The pump stops.
Output voltage of the pressure trans-
002
mitter is out of the pre-set range.
The pump stops and doesn't re-start.
Failure to reach the set pressure
003
within 120 sec. of continuous opera-
tion of the pump.
Overcharging of the battery with
protection tripping.
004
The pump stops.
Errors 00.. are displayed for about 30 seconds before being reset, but will display re peat-
edly in the event of permanent anomalies.
5. MAINTENANCE
The pump is robust, completely sealed, and requires very little daily maintenance. Compliance
with the following points, should help to maintain its optimum performance:

5.1) Thorough cleaning

Dust, sand and dirt are a danger for any hydraulic device.
Every day, after use, the pump and accessoires must be wiped with a clean cloth taking care to
remove any residue. Do not use Hydrocarbons to clean the rubber parts.
After use, protect the couplers of the pump, hose and hydraulic head with their protective
caps to prevent contamination.
17
Error description
S
olution
Repeat the work cycle, keeping the start but-
ton pressed down until the motor switches off
.
automatically.
Replace the battery.
If the problem persists, please contact Cem-
bre.
Press the release button, connect the fl exible
hose or check the correct connection to the
pump.
Wait for the display to turn off (60 sec.) or re-
move and re-insert the battery, then re-start the
pump. if the problem persists, please contact
Cembre.
Remove and re-insert the battery, if the problem
persists, please contact Cembre.
Repeat the work cycle; if the problem persists,
please contact Cembre.
Wait for the display to turn off (60 sec.) or re-
move and re-insert the battery, then re-start the
pump. if the problem persists, please contact
Cembre.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

B68m-p18aB68m-p18eB68m-p18t

Table des Matières