Dip switch
AUTOMATIC
1
CLOSING
2
2 / 4 STROKE
NO
3
REVERSE
DECELERA-
4
TION
5
PRE-FLASH.
6
FOTOTEST
7 - 8
2
RADIO CHANNEL operation (terminals no. 21 - 22)
nd
Dip 7 Dip 8 Function
Off
Off
Off
On
On
Off
On
On
OPENING
9
RAM BLOW
SENSITIVE
10
EDGE
IMPORTANT!
Each pair of terminals attached to an NC contact that is not in use must be short-circuited
in order to ensure the proper operation of the board.
The door's earthing system must comply with current standards. The manufacturer will
accept no liability for any damage deriving from failure to comply with this requirement.
18
after opening, the gate automatically closes when the delay set on
On
the T.C.A. trimmer expires;
Off
automatic closing disabled;
with automatic closing enabled, a sequence of open/close com-
On
mands causes the gate to OPENCLOSE-OPEN-CLOSE etc (see
also dip switch 3);
in the same conditions, the same command sequence causes the
Off
gate to OPEN-STOP-CLOSE-STOP-OPEN-STOP (step-by-step);
the gate ignores the close command while it is opening (NO RE-
On
VERSE);
Off
the gate behaves according to the position of dip-switch n° 2;
the deceleration function is on and can be adjusted by means
On
of the RALL trimmer (see "DECELERATION SETTING PROCE-
DURE");
Off
the deceleration function is off;
On
the pre-flashing function enabled;
Off
the pre-flashing function disabled;
On
the "photocell test" function is enabled;
the "photocell test" function is disabled. N.B.: to be used when the
Off
photocells are not used;
Gate contact open: The contact activates on opening the gate and remains
active during the open time, during the TCA and during reclosure. It
deactivates once the gate has completed its closure movement.
Bistable function active: the radio control impulse causes the contact to
activate and remain active until the subsequent impulse.
Monostable function active for 2 sec.: the radio control impulse causes the
contact to activate and remain active for 2 sec.
Monostable function active for 180 sec.: the radio control impulse causes
the contact to activate and remain active for 180 sec.
the "opening ram blow" function is on. This permits the release
of the electric lock (to be used only in the presence of an electric
lock);
On
With Software version 3.02 and later:
Wing opening delay increases by 3 seconds (for example, with
Software version 3.02 from 2 – 33 seconds to 5 – 36 seconds);
Off
the "opening ram blow" function is off;
On
RESISTIVE SENSITIVE EDGE (terminal no. 15)
Off
RESISTIVE EDGE - fixed edge (terminal no. 15)
D750M