TROUBLESHOOTING
PROBLEM.
No Power To Machine
Electrical Shock
Nuisance Tripping of
Circuit Breaker
Vacuum Motor Speed
Varies or Doesn't Run
Loss of Vacuum
26
CAUSE
Faulty power cord
Power switch failure
Faulty circuit breaker
Internal wiring problem
Equipment not grounding
Receptacle not grounded
Internal electrical problem
Dry brush
Faulty circuit breaker
Mechanical problem
Worn motor brushes
Motor worn out
Faulty switch
Faulty circuit breaker
Internal wiring problem
Loose vac dome
Crack in dome or poor joint
Damaged dome gasket
Lint or dirt clogging
vacuum intake screen
Accessory tool clogged
Internal electrical problem
EXP-IF 98499 11/15/04
SOLUTION
Replace
Test switch for continuity/Replace if necessary.
Test circuit breaker for continuity/Replace if
necessary.
With the machine unplugged, check for, and correct,
any loose wire connections inside the machine at the
switches and terminal block.
Follow grounding instructions exactly.
Have an electrician inspect the building's wiring.
Ensure that the machine's wiring matches the
appropriate wiring diagram. Check for and correct
any loose wire connections. Replace any wires or
components that have short circuits.
Turn brush motor and pump switches on with
machine tilted rearward (brush off floor). Lower
machine back to carpet slowly.
Test circuit breaker for continuity/ Replace if
necessary.
Higher amp draws may indicate a mechanical
problem. Find parts which are not moving freely and
repair or replace.
Replace
Replace
Replace
Replace
Check for and correct any loose wire connections.
Check dome over tank.
Replace or repair using acrylic plastic cement only.
Replace
With power off clean vac intake screen found in
dome.
Clean out tool, ensure free air flow.
Have a trained service technician inspect and repair
the machine.