Set Baud Rate
Select the baud rate by setting DIP switch position 8 (see below). The change will take
effect immediately.
The Fronius Smart Meter supports programmatic baud rates up to 115200.
Multi meter sys-
tem - Explanation
of symbols
18
Grid
supplies the loads in the system if insufficient power is being generated
by the PV modules or supplied by the battery.
Inverter in the system
e.g. Fronius Primo, Fronius Symo, etc.
Fronius Smart Meter
measures the metering data relevant for the billing of electricity quantit-
ies (primarily the kilowatt hours of grid purchases and grid power feed).
On the basis of the data relevant for billing, the electricity retailer
invoices a grid purchase and the purchaser of the surplus pays for the
grid power feed.
Primary meter
records the load curve of the system and makes the measured data
available for energy profiling in Fronius Solar.web. The primary meter
also regulates the dynamic feed-in control.
Baud Rate
DIP Switch 8
9600 (default)
0 (OFF)
38400 (default)
1 (ON)