Create Or Edit A Dilute Program - MANOSTAT Compulab 3 Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CREATE OR EDIT A DILUTE PROGRAM

For use as a diluter, the pump is first primed with the diluent. Then, a dilute cycle consists of two separate actions,
sample and delivery. For the sample action, the outlet end of the tubing is placed in the container holding the sample.
The pump runs opposite the programmed direction to draw the sample volume into the tube. For the delivery action, the
outlet end of the tubing is moved to the receiving container, and after the hold time, the delivery volume is pumped out of
the pump. The sample volume plus the diluent volume equals the delivery volume.
To create a new dilute program, ensure that the console displays the PROGRAM MENU. If any other menu appears,
press the BACK key until the PROGRAM MENU is displayed.
Press the arrow under NEW to create a new program or press the arrow under EDIT to select a program to revise.
Follow the flowchart in Figure 12 to create or edit a dilute program.
REQUIRED PARAMETERS
ENTER PUMP TYPE,
TUBE SIZE, AND RATE
ENTER VOLUME
AND DIRECTION
ENTER UNITS
FOR VOLUME
OPTIONAL PARAMETERS
ENTER ACCEL, DECEL, AND HOLD
ENTER BEEP TIME AND NO-DRIP
ENTER NUMBER OF CYCLES;
TOGGLE MANUAL OR AUTO
(0 CYCLES IS NO LIMIT)
ENTER DELAY TIME BETWEEN
AUTO CYCLES
INPUT A PROGRAM NUMBER
(1 – 30)
AND PRESS
ENTER
TO SAVE
PRESSING
ENTER
WITHOUT ENTERING
A NUMBER RUNS THE PROGRAM.
(
REFER TO RUNNING A DILUTE PROGRAM
PROGRAM MENU
LINKED:NONE
NEW
EDIT:##
DILUTE MENU
DILUTE MENU
DRIVE:RD2
DRIVE:RD2
DILUTE MENU CONT.
DILUTE MENU CONT.
SMP:
SMP:
0.0mL DLV:
0.0mL DLV:
UNITS MENU
UNITS MENU
MILLILITER
MILLILITER
LITER
LITER
SAVE PROGRAM
SAVE PROGRAM
PROGRAM NUMBER:0
PROGRAM NUMBER:0
)
Figure 12. Dilute Menus
LOAD
LINK
ENTER CONTINUES #1
ENTER CONTINUES #1
TUBE:0
TUBE:0
RATE:
RATE:
0.0mL/MIN
0.0mL/MIN
ENTER CONTINUES #1
ENTER CONTINUES #1
0.0mL DIR:CW
0.0mL DIR:CW
PUMP
ENTER CONTINUES #1
ENTER CONTINUES #1
DILUTE OPTIONS
DILUTE OPTIONS
ACCEL:0.0s
ACCEL:0.0s
DECEL:0.0s
DECEL:0.0s
MORE DILUTE OPTION
MORE DILUTE OPTION
BEEP: 0.0s
BEEP: 0.0s
NO-DRIP: 0
NO-DRIP: 0
CYCLE SETTINGS
CYCLE SETTINGS
CYCLES:
CYCLES:
1
1
MAN/auto
MAN/auto
CYCLE SETTINGS
CYCLE SETTINGS
CYCLES:
CYCLES:
1
1
AUTO/man
AUTO/man
ENTER CONTINUES #1
ENTER CONTINUES #1
0 = NOT SAVED
0 = NOT SAVED
12
PUMP
#1
PUMP
MORE
MORE
PUMP
OPTIONS
OPTIONS
PUMP
ENTER CONTINUES #1
ENTER CONTINUES #1
HOLD:0.0s
HOLD:0.0s
MORE
MORE
PUMP
ENTER CONTINUES #1
ENTER CONTINUES #1
CYCLE
CYCLE
PUMP
ENTER CONTINUES #1
ENTER CONTINUES #1
PUMP
ENTER CONTINUES #1
ENTER CONTINUES #1
DELAY:
DELAY:
0.0s
0.0s
PUMP

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

72-777-10072-666-10072-767-000

Table des Matières