Servicing; Product Specifications - patura P30 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

terminals with a PATURA Fence Compass, DVM or Fence Tester. If the voltage is less than
6 kV, request your PATURA service agent to check the energiser.
Check the energiser earthing. Use the procedure described in "Installing and testing an
earth system" on page 27.
Check your fence system for faults. The most common source of low voltage is faults on
the fence line.
If the fence, earth and energiser are in good condition and the voltage is still below 4 kV,
talk to your PATURA distributor. They will help you identify whether recent extensions to
your fence, a poor fence layout, or soil conditions may be causing inadequate voltage.
How do I locate faults?
The recommended tool for locating faults is the PATURA Fence Compass. This combined
vol-tage and current meter allows you to rapidly locate sources of current leakage.
Alternatively, use a PATURA DVM or Fence Tester. Use cut-out switches to turn off the
power to different sections of the electric fence. If the voltage on the fence increases when
a section of the electric fence is turned off, then investigate that section for possible faults.
There are no lights flashing on the energiser.
Check the power supply. Ensure that the power is switched on. If the energiser still does
not operate, request your PATURA service agent to check the energiser.

Servicing

This energiser contains no user serviceable parts. It must be returned to a PATURA-
appointed service agent for repair.
Product Specifications P30
Power Supply
Power Consumption
Output voltage
Max. Output energy
Stored energy
Dimensions (WxHxD)
Weight
Slow (1)
Fast (2)
No Load
500 ohms
- 31 -
6 V dc
13 mA (6 V)
24 mA (6 V)
8.0 kV
2.0 kV
0.12 J at 2000 ohms
0.16 J
105x265x100 mm
0.6 kg