Using the charger for the fi rst time
Can cel
Disc harge
Bal ance
Mod e
Can cel
Disc harge
Bal ance
Mod e
Can cel
Disc harge
Bal ance
Mod e
2. „Mode" button is pressed once: Setting the lower balancer voltage
limit. The single cell voltage of the balanced battery must be above this
voltage, so the process is started.
Press the
or
press the „Mode" button again.
Factory setting: 3.3 V - for Li-Po battery, for LiFe batteries the voltage
must be changed to 2.9 V.
Note: Never set the voltage below the minimum voltage allowed
for your battery, this can damage the battery! The minimum voltage
is indicated on the battery!
3. „Mode" button is pressed twice: Setting the discharge voltage limit. At-
tention: check the minimum storage voltage of the connected battery
type!
Press the
or
press the „Mode" button again.
Factory setting: 3.9 V - for Li-Po battery, for LiFe batteries the voltage
must be changed to 3.2 V.
Note: Never set the voltage below the minimum voltage allowed
for your battery, this can damage the battery! The minimum voltage
is indicated on the battery!
4. The balancer goes back to the basic display.
button to change the voltage. To save the settings,
button to change the voltage. To save the settings,
Using the charger for the fi rst time