3 TRANSMISSION PROTOCOL / PROTOCOLE DE TRANSMISSION /
PROTOKOLLÜBERTRAGUNG
3.1 Standard Mode
General Clear
Time of day or Running time
Running time difference (time from the first finisher)
Number and Net Time
Text (for GEMINI 12 alphanumeric characters in text mode only)
LF
nnn
tttttttttttt
xx
XX
YY
:
Example
tttttttttttt:
Header
R02
S02
S03
S13
3449.500
: indicates display line from 1 (no LF) to 15 (with 14 LF)
: bib number
: time in the chosen format:
Hh:Mm:Ss.dcm
Mm:Ss.dcm¬¬¬
m:Ss.dcm
: indicates the time format:
the first (x) indicates the number of the digit after STX
The second (x) indicates the number of the first digit to be displayed
01 23 45 678
Hh:Mm:Ss.dcm
: horizontal position (00 to 99)
: vertical position (00 to 99) [= line number -1]
12:34:56.789
34:56.78
34:56.78
4:56.789
Error
Version 2.7
¬¬¬45:02.6
Display
45:02.6¬
45:02.6¬
5:02.6¬¬
Error
GEMINI
1:13:57.004
Error
Error
Error
3:57.004