MAINS CONNECTION
Connect only to single-phase AC system voltage as indicated on
the rating plate. It is also possible to connect to sockets without an
earthing contact as the design conforms to safety class II.
Appliances used at many different locations including wet room
and open air must be connected via a residual current device (FI,
RCD, PRCD) of 30mA or less.
Only plug-in when machine is switched off.
Inrush currents cause short-time voltage drops. Under unfavoura-
ble power supply conditions, other equipment may be affected. If
the system impedance of the power supply is lower than 0,2 Ohm,
disturbances are unlikely to occur.
SPECIFIED CONDITIONS OF USE
The angle grinder is intended for grinding and cutting metal,
stone, concrete and ceramic materials as well as sanding and wire
brushing.
Use the cutting guard from the accessories range for cutting
application.
Please refer to the instructions supplied by the accessory
GB
manufacturer.
The machine is suitable only for working without water.
Only appropriate grinding or cutting discs and related guards
(grinding guard or cutting guard) as described in the product
specification section of this manual should be fitted to the angle
grinder. The angle grinder is designed for handheld use; it is not to
be mounted onto a fixture or workbench.
Do not use the product in any way other than those stated for
intended use.
WORKING INSTRUCTIONS
For accessories intended to be fitted with threaded hole wheel,
ensure that the thread in the wheel is long enough to accept the
spindle length.
Always use and store the cutting and grinding wheels according to
the manufacturer's instructions.
Always use the correct guard for cutting and grinding.
The grinding surface of the centre depressed wheels must be
mounted min. 2 mm below the plane of the guard lip.
The adjusting nut must be tightened before starting to work with
the machine.
Always use the auxiliary handle.
The workpiece must be fixed if it is not heavy enough to be steady.
Never move the workpiece towards the rotating wheel by hand.
The flange nut must be securely tightened before the machine is
started. If the tool is not securely tightened with the flange nut, it
is possible that the tool will lose the required clamping force when
it is decelerated.
ELECTRONICS
The machine has an overload and anti-kickback safety function
and stops if it is overloaded.Please note that the machine will
automatically accelerate back to its original operating speed if the
load is removed from it.After it has reached its operating speed the
machine is ready for use again.
English
16
RESTART PROTECTION
The power tool is supplied with a restart protection. This prevents
the switched-on power tool from starting by itself when the power
tool is connected to the power source and from restarting after a
failure of the power supply. If the cutting wheel is outside of the
workpiece switch off the power tool and then switch it back on
again in order to continue to work. If the cutting wheel is inside
of the workpiece wait until the wheel comes to a complete stop,
disconnect the plug from the power source, remove the wheel from
the cut, switch off the power tool, connect the power tool to the
power source and then switch the power tool back on again in order
to continue to work.
STARTING CURRENT LIMITER
The starting current for the machine is several times greater than
rated current. The starting current limiter reduces the starting cur-
rent to such an extent that a fuse (16 A, slow-blow) is not tripped.
SOFT START
Electronic soft start for save use prevents jerky run-up of the
machine.
BRAKING SYSTEM
The brake engages when the trigger is released, causing the wheel
to stop and allowing you to proceed with your work. Generally, the
wheel stops within six seconds. If it takes longer than six seconds,
ensure that you have the correct accessories installed and try again.
If the problem still occurs, the tool needs servicing by an authorized
MILWAUKEE service facility. Make sure the tool comes to a complete
stop before laying it down.
MAINTENANCE
Always disconnect the plug from the socket before carrying out any
work on the machine.
The ventilation slots of the machine must be kept clear at all times.
If the replacement of the supply cord is necessary, this has to be
done by the manufacturer or his agent in order to avoid a safety
hazard. Use only Milwaukee accessories and Milwaukee spare
parts. Should components need to be replaced which have not been
described, please contact one of our Milwaukee service agents (see
our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state
the Article No. as well as the machine type printed on the label
and order the drawing at your local service agents or directly at:
Techtronic Industries GmbH, Max-Eyth-Straße 10, 71364 Winnen-
den, Germany.