Electrical Work
■
Electrical requirements
- This appliance must be supplied with the proper voltage and frequency, and
connected to an individual, properly earthed branch circuit, protected by a
circuit breaker or fuse. (The rating plate is on the bottom of the appliance.)
- This appliance is not fitted with other means for disconnection from
the supply mains having a contact separation in all poles that provide
full disconnection under overvoltage category III conditions. Means for
disconnection must be incorporated in the fixed wiring in accordance with
the wiring rules.
- You must use a two-wire, single-phase A.C. 220-240 V, 40 A, 50 Hz
electrical system. (It is also possible to use a four-wire, three-phase.)
If you connect to aluminum wiring, properly use connectors approved for
use with aluminum wiring.
- Check with the local utilities for electrical codes applied in the area.
Failure to wire the appliance according to governing codes may result in a
hazardous condition.
- After installation, show the customer where the breaker for the appliance is
located.
■
Installation of the earth leakage circuit breaker
- In accordance with the electrical wiring rules, incorporate the earth leakage
circuit breaker in the home electrical wire.
- Follow the specification of the earth leakage circuit breaker as follows.
Rated current: 40 A, rated sensitivity current: 30 mA
12
WARNING
Electrical work must be
performed by a legally
qualified electrician.
■
Electrical connections
1. Turn off power.
Turn off power at the circuit breaker or remove fuses to the appliance
branch circuit.
2. Connect the power cord.
Connect the power cord in accordance with all governing codes and
ordinances.
- Single-phase connection (220-240 V ~ 50 Hz)
Connect the wires in accordance with the instructions given in the
following table and diagram:
Electirical cable
Wire connection
E: Yellow / Green
E
(Connect to the earth terminal)
N
N: Grey and Blue together
L: Black and Brown together
L
(Connect to the live terminal)
- Three-phase connection (380-415 V 2N~ 50 Hz)
Separate the L wires and connect them in accordance with the
instructions given in the following table and diagram:
Electirical cable
Wire connection
E: Yellow / Green
E
(Connect to the earth terminal)
N
N: Grey and Blue together
L1
L1: Black
L2: Brown
L2
(Connect to the live terminal)
13