CargoMaster 6400 E
No.
Fault
1.
Vehicle does not move
2.
Power of the vehicle is
too weak
3.
Vehicle does not brake
or not brake sufficiently
4.
No display of the
charge at the charger
or display flashes
5.
The daily radius of
action is no longer
reached
agria-Werke GmbH • D-74219 Möckmühl • Tel. +49 (0) 6298-390 • Fax. +49 (0) 6298-39100 • e-mail: info@agria.de • Internet: http://www.agria.de
Cause
a.)
Main switch non switched on
b.)
Left safety switch not activated
c.)
Turning handle activated when switching on
d.)
After 10 min the control was on stand-by
e.)
Release lever of the stop brake released
f.)
Fuse is faulty
g.)
Cable of battery has got loose
h.)
Cables of the operating elements are broken
off
i.)
Operating elements or their cables are faulty
k.)
Battery not charged. Control system
switches off
a)
Battery not charged or partially discharged
b)
Electronic control overheated
c)
Vehicle overloaded
d)
The collector coals of the motor are strongly
used
e)
Motor defect
a)
Release lever of the stop brake released
b)
The vehicle is overloaded and the stop brake
can no longer retain it on steep terrain
c)
The brake disks of the drive are strongly
used.
a)
Mains plug not connected / no supply
voltage
b)
Fuse at the charging current circuit faulty
c)
Batteries faulty
a)
The batteries are not charged completely.
The charging time is too short.
b)
The tyre pressure is too low. As a
consequence the rolling resistance
increases and with that the energy
consumption increases clearly.
c)
The capacity of the batteries decreases in
in relation to their age.
Measures to take
a) Switch on
b) Activate the lever control in addition to the
turning handle
c) Turning handle to 0-position and activate
again
d) Switch the main switch OFF and ON again
Info: After switching off wait 5 seconds
before switching on again, as the electronic
system must reset to the initial position
e) Engage the release lever again
f)
Replace battery fuse 80A and replace
control fuse 1A
g) Tighten the pole screws. Follow the safety
instructions
h) Plug-in the cables again
i)
Have the elements replaced by the agria-
service
k.) Immediately connect it to the charger.
Or battery was not charged, because
charging fuse is faulty. Replace fuse 6,3 A.
Or charging socket faulty: service
Or charger faulty
a) Immediately connect to the charger
b) Let the control cool for a few minutes and
reduce the effective load
c) Reduce the effective load
d) have them replaced by the agria-service
e) have the elements replaced by the
agria-service
a) Engage the release lever again
b) Reduce the effective load
c) Remove the motor, send it to the supplier
and have it repaired
a) Connect the mains plug / establish power
supply
b) Replace screwed fuse 6,3 A at the charging
Current circuit
c) Replace both batteries
a) Prolong the charging time.
b) Correct the tyre pressure.
c) Replace the batteries with new ones.
Chap.
5
5
5
8
11
16
12
12
11
16
3
33