Electrical Connection - Pentair Jung Pumpen HEBEFIX PLUS Instructions De Service

Masquer les pouces Voir aussi pour HEBEFIX PLUS:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ENGLISH
Make sure that there are no toxic gases in the working area.
Observe the health and safety at work regulations and make
sure that a first-aid kit is to hand.
In some cases, the pump and the pumping medium may be hot
and could cause burns.
For installations in areas subject to explosion hazards, special
regulations apply!
APPLICATION
The HEBEFIX PLUS is designed for discharging domestic
wastewater from household washing machines and dishwash-
ers, sinks, showers and bathtubs. A maximum of three units to
be drained can be connected and these must be located in the
same room.
The Hebefix plus has four connection pieces marked at the
side and one connection piece marked at the top which can be
used for attaching pipes with an outer diameter of 50 mm (40
mm at the top) using connection sleeves or plug-in seals.
NOTICE! The HEBEFIX PLUS must not be used to dispose of
sewage from toilets and urinals.
When using the pump, the relevant national laws as well as
national and local regulations must be complied with, for ex-
ample:
• Domestic contaminated water and wastewater (e.g. EN
12056 in Europe)
• Installation of low voltage systems (e.g. VDE 0100 in Ger-
many)
Temperatures
The media pumped must have a temperature of not more than
35°C (95°F).
The Hebefix plus is frost-resistant down to -20°C when stored
in dry conditions. When installed, however, the residual water
in the system must not be allowed to freeze.
EMC
If installed in compliance with the regulations and used prop-
erly, then this appliance meets the protective requirements of
the EMC directive 2014/30/EU and is suitable for domestic use
and connection to a power supply from the grid.
Scope of supply
Hebefix plus, 1¼" swing-type check valve, instruction man-
ual, accessories bag with elbow, 2 reducing adapters, 8 hose
clamps, 3 connection sleeves, 4 plug-in seals, 2 rawlplugs, 2
screw hooks and a sealing plug, ventilation accessories (ven-
tilation grille, small active carbon filter for tank, round active
carbon filter for front wall, shim disc and sealing plug)
10

ELECTRICAL CONNECTION

WARNING!
The HEBEFIX PLUS must only be connected to sockets that
have been installed properly in accordance with the regula-
tions and and are protected with at least 10 A (slow) and FI-
safety switches (30mA).
NOTICE! Only qualified electricians may carry out electrical
works to the pump or the control units.
The relevant standards (such as EN standards), country-spe-
cific regulations (such as VDE in Germany), and the regulations
of the local power supply companies must be observed.
NOTICE! Never put the mains plug in water! If water gets into the
plug, this can cause malfunctions and damage.
Observe the operating voltage (see type plate)!
Use the plug unit only in well-ventilated rooms which are pro-
tected from splash water and flooding. No additional motor
protection is required, since the system has an integrated
winding thermostat.
NOTICE! The plug must be easily accessible even when moun-
ted in a system duct.
Unacceptably high temperatures cause the thermostat to shut
down the motor.
WARNING!
After the thermostat has switched off the system, pull out the
mains plug before remedying the fault, since the appliance can
switch itself on again automatically if the power is still con-
nected!
The control unit
HEBEFIX PLUS has a level controller that switches the pump
on and off depending on the level of the water.
If HEBEFIX PLUS runs but does not reach the switch-off point
within approx. 50 ± 5 seconds, then the alarm will sound. A loud
alarm tone sounds but the pump carries on running.
The alarm persists as a permanent alarm, the potential free
alarm contact K1 (40/41) is closed and can be used for remote
alarm transmission.
Disconnecting the mains plug acknowledges the alarm warn-
ing or switches the unit off in the event of a fault. The inspec-
tion opening must be removed to access the mains plug.

Publicité

Table des Matières
loading

Table des Matières