Operation And Maintenance; Getting Started; Vibrating Poker Connection To The Converters; Converter Connection To The System - ENAR ENARCO BOXEL M2 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

(the converter feeding voltage should not vary than +/- 5% as stated on the converter plate.
The level of acoustic pressure is less than 70 dB. Proper protective equipment should be used when
the noise level gets to be more than 70 dB.
Respect the maximum number of vibrating pokers that can be connected to the converter.
Avoid having the converter working unloaded during long periods of time. The vibrating pokers
should not be working out of concrete. Switch on the poker before starting working an disconnecting
them immediately after finishing the vibrating operation.
When finishing the job or when taking a break, the operator should switch off, disconnect it from the
electrical system, place it in such a way that should not fall or tip
This screed can be used only under the applications for which it has been designed and according to
these safety instructions.
When working with a petrol screed:
The acoustic power level of this machine can reach 95 dB. Proper protective equipment should be
used.
IN ADDITION, LOCAL COUNTRY STABLISHED ORDINANCES SHOULD BE RESPECTED.
4

OPERATION AND MAINTENANCE

4.1 GETTING STARTED

Read item 3 USAGE CONDITIONS

4.2 VIBRATING POKER CONNECTION TO THE CONVERTERS

The converter has a socket to connect the vibrating pokers.
Connection possibilities:
The input current of the pokers connected in load shall not exceed the out current specified in the
electrical characteristic table.

4.3 CONVERTER CONNECTION TO THE SYSTEM

Check the converter switch is off before connecting to the system.
Unless otherwise stated at the time of ordering, the frequency converters model AFE2000 and
AFE1000 will be connected at the factory as three phase, 380 V 50 Hz. The models AFE 2000M
and AFE1000M, will go out of the factory to be used as 220 V 50 Hz single phase charge.
Disconnecting the equipment:
First, stop the vibrating pokers by turning off the proper switch, second stop the converter by turning
off the proper switch, and finally remove the feeding cable from the system.
Earth connection.
FRECUENCY CONVERTERS
AFGH2000, AFGB2000, AFDY2000, AFDH4500, AFE, BOXEL
- Read the motor manufacturer's manual before working.
- Do not work in closed rooms, the exhaust fumes may be toxic.
-·Wait 2 minutes for the petrol refill until the motor get colder.