Alarms And Warnings - Primer DSD-11 Guide Rapide

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

A table is then displayed with the default parameters configured for each program.
PROGRAM
1
2
3
4
5
6
7
8
9

2 ALARMS AND WARNINGS

The open door and open filter alarms lead to the pausing of the current program. When the
conditions triggering the alarm disappear, the drying cycle can be restarted as soon as the alarm is
closed. The other alarms stop the programme and a warning alarm is heard. This warning is
stopped by pressing SELECT or by removing the reason for the alarm.
The following table lists the alarms and their possible causes.
Alarm
Meaning
AL-1
Door open
AL-2
Filter cover open
AL-3
No flame
AL-4
Pressure drop failure
or insufficient air flow
AL-5
Motor-fan overload
AL-6
Over temperature
AL-7
Dirty filter
AL-9
Probe Alarm
If any of the previous alarms were to persist, consult your Technical Assistance Service. Always
use the machine's serial number for your queries.
38
RECOMMENDED
USE
TOWELS
COTTON 1
COTTON 2
SYNTHETICS
DELICATES
INTENSIVE 1
INTENSIVE 2
EXTRA 1
EXTRA 2
Possible Solutions
* Close the door.
* Close the cover.
* Check gas supply cock open.
* Check that the pressure is correct
* Check that the outlet conduit is free, check that it is
not too long.
* Check that the filter is fluff-free.
* Check that the fan's turbine is fluff-free.
* Check that the outlet conduit is correctly connected, and
does not have a free outlet.
* Check that the air flow is correct.
* Check gas pressure is correct.
* Clean the filter.
* Clean filter more regularly, do not reach this point
* Problem with the temperature and/or humidity probes.
Contact your Technical Assistance Service .
DRYING
Min
ºC
%RH
30
80
35
75
40
65
20
60
25
45
20
75
30
75
15
90
20
90
ROTATION
TIME
25
70
25
70
30
70
30
70
30
70
30
70
30
70
20
30
15
30

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dsd-17

Table des Matières