We are pleased you have purchased our product and we thank you for your trust in us. We aim atfully satisfying
our customers by offering them state-of-the-art products for the treatment of respiratory diseases.
Read these instructions carefully and retain them for future reference. Only use the accessory as de-
scribed in this manual. This is a home medical device to nebulise and administer medication prescribed
or recommended by your doctor upon assessing the patient's general conditions. Please note that the full
range of Flaem products is visible on the website www.flaem.it.
THIS DEVICE COMES EQUIPPED WITH:
A - Aerosol Therapy Device
A1 - Switch
A2 - Air outlet port
A3 - Air filter
A4 - Nebulizer port
A5 - Socket for power cord
A6 - Power cord
B - Connection tube (main unit / nebulizer)
C - Accessories
C1 - RF6 Basic
nebuliser
2
C1.1 - Lower part
C1.2 - Complete nozzle
C1.3 - Upper part
C1.4 - Cap
C2 - Mouthpiece
C3 - Adult mask (PVC)
C4 - Child mask (PVC)

IMPORTANT SAFEGUARDS

• This M.D. is also intended for direct use by the patient.
• Before using the product for the first time, and periodically during its lifetime, check the integrity of the device
structure and of the power cable to make sure there is no damage. In the event of damage, do not plug in the
cable and immediately take the product to an authorised FLAEM service centre or to your trusted dealer.
• Should your device fail to provide the expected performance, contact the authorised service centre for
clarifications.
• The expected medical life of the accessories is 1 year. It is, however, advisable to replace the nebuliser cup every 6
months in the event of intense use (or earlier if the cup is obstructed) to always guarantee maximum therapeutic
efficacy.
• Children and people who are not self-sufficient must use the device under the close supervision of an adult who
has read this manual.
• Some parts of the device are small enough to be swallowed by children; therefore, keep the device out of the
reach of children.
• Do not use the supplied tubing and cables for anything other than their intended use. These parts could cause a
strangling hazard: pay close attention to children and persons with particular difficulties as they are often unable
to accurately evaluate danger.
• The apparatus is unsuitable for use in presence of flammable anaesthetic mixture with air, oxygen or nitrous
oxide.
• Always keep the power supply cable away from hot surfaces.
• Keep the power cable away from animals (for example, rodents) which could damage the insulation.
• Do not handle the device with wet hands. Do not use the device in damp environments (for example, while taking
a bath or shower). Do not immerse the device in water; in the event of immersion immediately disconnect the
plug. Do not remove or touch the immersed device; unplug the power cable first. Immediately bring the device
to an authorised FLAEM service centre or to your trusted dealer.
COMPLETE SYSTEM FOR AEROSOL THERAPY
Mod. P0406EM F700
C5 - RHINO CLEAR® Nasal shower
C5.1 - Nasal transparent adapter "A", suitable for children
C5.2 - Separator
C5.3 - Atomizer
C5.4 - Shower body with ergonomic handle
C5.5 - Dispensing button
C6 - Nasal shower-tube connect fitting
E - Carrying bag
F - "Lella the Ladybug" fairy tale
7
up to 3 years of age
- Nasal white adapter "B", suitable for children 3 to
10 years old
- Nasal blue adapter "C", suitable for children 10
years old and up
C5.4.1- 10 ml nebulization chamber
C5.4.2 - Collection chambre
C5.5.1 - Button
C5.5.2 - Rubber cap