We are pleased you have purchased our product and we thank you for your trust in us.
It is very important that the health care worker, the person trained in use or the patient read and understand

INTENDED USE

ASPIRA Go is an aspirator designed for medical and surgical use in healthcare centres such as hospitals, for home care
and for pharyngeal suction for permanent tracheotomy. The device generates a negative pressure (suction) which
allows fluids to be extracted through a single use tube connected to a collection canister which retains the fluids until
they can be properly disposed of. Use of the device must be prescribed by a doctor.

PRODUCT DESCRIPTION

ASPIRA Go (1) is equipped with a vacuum flow adjustment knob (4), vacuum gauge (3) and 1000 ml canister (9) with
inflow safety device (10) to prevent fluids from entering the suction pump. This device interrupts the vacuum flow
via a float-controlled valve found in the canister lid. It does not require lubrication, is manageable, simple to use,
reliable, resistant and quiet. This model comes with a rechargeable battery. ASPIRA Go is equipped with the following
FLAEM accessories: 1000 ml canister (9) with inflow safety device (10), Power cable for vehicle power outlets (20),
multi-voltage power supply (19), Connection tubes (6/8/14), Disposable cannula for aspirator (16), Disposable manual
aspirated flow control (15) and Hydrophobic antiviral/antibacterial filter for single patient use (7).
NOTE: Only use original FLAEM accessories and spare parts, we disclaim any liability in the event of using non
original spare parts or accessories.
DEVICE NOMENCLATURE
1) SUCTION MACHINE
2) ON/OFF SWITCH
3) VACUUM GAUGE
4) VACUUM FLOW ADJUSTMENT KNOB
5) AIR INLET
6) CONNECTING TUBING
7) HYDROPHOBIC ANTIVIRAL/
ANTIBACTERIAL FILTER (FOR SINGLE PATIENT USE)
8) CONNECTING TUBING
9) COLLECTION CANISTER
10) SAFETY DEVICE

IMPORTANT NOTICES

The manufacturer makes every effort to ensure that every product is of the highest quality and safety; however, as for
any electrical device, basic safety regulations must always be followed in order to avoid harming persons and things.
• The medical device must NOT be used in the operating theatre, for drainage or for thoracic drainage or on
vehicles such as ambulances or emergency vehicles.
• The Medical Device is not suitable for use in MRI premises (Magnetic Resonance Imaging)
• Carefully follow the user and maintenance instructions to assure proper operation and to extend the service life
of the device.
• Before using the product for the first time, and periodically during its lifetime, check the integrity of the device
structure and of the power cable to make sure there is no damage. In the event of damage, do not plug in the cable
and immediately take the product to an authorised FLAEM service centre or to your local dealer.
• Do not perform any maintenance operations while the device is being used on a patient.
• In the presence of children and non self-sufficient individuals, the device must be used under the close supervision
of an adult who has read this manual.
• Some parts of the device are small enough to be swallowed by children; keep the device out of the reach of children.
• Do not use the provided tubing and cables for any other purpose than those specified, as they can cause risk of
strangulation. Be particularly attentive with children and individuals with disabilities because they are often unable
to correctly assess risk.
• The suction machine is intended exclusively for the collection of NON-flammable fluids. It is not suitable for use in
the presence of a flammable anaesthetic mixture with air, or with oxygen or nitrous oxide.
• Always keep the power supply and the power cable away from hot surfaces.
• Keep the power supply cable away from animals (for example, rodents) which could damage the insulation.
• Do not immerse the device in water; in the event of immersion disconnect the plug immediately. Do not remove
or touch the immersed device; unplug the power cable first. Immediately bring the device to an authorised FLAEM
the information for use and maintenance.
11) CANISTER LID
12) CANISTER "VACUUM" INLET
13) CANISTER "PATIENT" INLET
14) CONNECTING TUBING
15) MANUAL VACUUM
16) ASPIRATOR TIP
17) ACCESSORY COMPARTMENT
18) EXTERNAL POWER OUTLET
19) MULTI-VOLTAGE POWER SUPPLY
20) VEHICLE POWER OUTLET CABLE