INTRODUCTION
The dosing pump is comprised of a control unit that houses the electronics and the magnet, and a hydraulic part in
contact with the liquid to be dosed.
149,9
4
3
6
5
The parts in contact with the liquid have been chosen in order to guarantee perfect compatibility with most chemical
products normally in use. Given the range of chemical products available on the market, we recommend checking
the chemical compatibility of the dosed product and contact materials.
FOR SPECIFIC HYDRAULIC FEATURES SEE THE LABEL ON THE PUMP
MATERIALS USED IN THE PUMP HEAD (STANDARD)
Body:
Ball valves:
Spheres:
Diaphragm:
The pumps are supplied complete with the indispensable accessories for their correct installation. You will find the
following in the packaging:
Foot filter, injection valve, transparent suction tube, transparent tube for bleed valve, opaque delivery tube, Pump
fixing inserts, bracket for wall mounting, level sensor connector and instruction manuals
Read the following precautions carefully before proceeding with pump installation or maintenance.
Always disconnect the power supply before installing or carrying out maintenance on the product.
We recommend installing the pump in a vertical position to ensure proper operation.
H
SO
SULPHURIC ACID All the pumps are tested with water. When dosing chemical products that may react
-
2
4
with water, dry all the internal parts of the plumbing thoroughly.
Install the pump in a zone where the environment temperature does not exceed 40ºC and the relative humidity
-
is below 90%. The pump has an IP65 protection level. Avoid installing the pump directly exposed to sunlight.
Install the pump so that any inspection and maintenance operations are easy to carry out, then secure the pump
-
firmly in order to prevent excessive vibrations.
Check that the power supply available in the network is compatible with that indicated on the pump label.
-
If you are injecting in pressurised pipes, always make sure that the system pressure does not exceed the maximum
working pressure indicated on the dosing pump label before starting up the pump
EM00136915
PVDF
PVDF
Ceramic
PTFE
PRECAUTIONS!
Product intended for professional use, by skilled people.
Follow the safety procedures relative to the dosed product.