d) Selecting the Start Address for the DMX Projector
All DMX-controlled devices need a digital start address so that the correct device responds to the signals. This digital
start address is the channel number from which the device starts to "listen" to the digital commands from the DMX
controller. Enter the correct number and read it from the display located on the base of the VDP250MH7.
You can use the same starting address for a whole group of devices or enter an individual one for every device.
When using one single address, all the units will "listen" to the control signal on one particular channel. In other
words: changing the settings of one channel will affect all devices simultaneously. If you set different addresses,
each device will "listen" to a separate channel number. Changing the settings of one channel will only affect the
device in question.
In the case of the 7-channel VDP250MH7, you will have to set the start address of the first device to 1, the second
unit to 8 (1 + 7), the third to 15 (8 + 7), and so on.
e) Setting Up the Device
Use the three push buttons and the display to set the various functions. When you turn on the device, the display
setting will be the same as when you turned it off.
Press the MENU button until the letter 'd' appears in the LED display above the button. Then use the UP and DOWN
keys to set the DMX address in the 3-digit LED display.
Other operation modes are shown on the rear panel of the device (e.g. music-controlled).
6. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections ...
3. Mechanically moving parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts, apart from the lamp and the fuse (see "4. Installation").
8. Contact your dealer for spare parts if necessary.
7. Technical Specifications
Power Supply
Power Consumption
Fuse
Dimensions
Total Weight
Lamp
Max. Ambient Temperature
Max. Housing Temperature
The information in this manual is subject to change without prior notice.
VDP250MH7 – PROFESSIONEEL 7-KANAALS MOVING HEAD
1. Inleiding en kenmerken
Dank u voor uw aankoop! Uw VDP250MH7 kan worden aangestuurd door eender welk DMX512-toestel. Als het toestel
werd beschadigd tijdens het transport, stel dan de installatie van het toestel uit en raadpleeg uw dealer. Lees deze
handleiding grondig voor u het toestel in gebruik neemt.
VDP250MH7
max. 230Vac/50Hz
max. 350W
2A, 250Vac (5 x 20mm) (order code FF2N)
300 x 480 x 300 mm
17.2 kg
1 x 230V/250W MSD (order code LAMP250MSD)
45°C
130°C
4
VELLEMAN