LED
In normal operating mode, the LED indicator blinks to indicate that signals are being transmitted in the following situations:
When movement is detected in flat battery conditions.
When the cover is opened and the tamper switch is actuated.
When movement detected if the tamper alarm condition persists.
When motion is detected in Test mode.
When the Test button is pressed in tamper alarm conditions or if the battery of the detector is flat.
The LED does not blink if the tamper switch and the battery detector are normal and not in Test mode.
The LED blinks rapidly twice to confirm reception by the control unit.
Jumper
If the jumper is set to OFF (if the jumper connection is removed or positioned on only one pin), the detection sensitivity is at
normal level.
If the jumper is set to ON, the detection sensitivity of the detector is maximum.
In the 1051/101 model the default position is OFF, in the 1051/102 model the default position is ON.
Tamper
The tamper switch protects the detector from unauthorised opening of the cover.
Test mode
The detector can be set to Test mode by pressing the Test button on the front cover for a few seconds. In Test mode the sleep time will
be deactivated and the LED indicator will blink whenever motion is detected. Whenever the Test button is pressed, the detector
transmits a test signal to the control unit to test the wireless communication range and goes to Test mode for 3 minutes. It automatically
exits Test mode after 3 minutes and goes back to normal mode.
SLEEP TIME
time between the detection of a movement and the next movement
Learning procedure
Extract the battery isolator to activate the battery.
The LED will blink for 30 seconds (the detector is being initialised). During initialisation, the detector will not be activated. It
is advisable not to generate any alarms during this time. Once the initialisation time has finished, the LED will switch off and
the detector is ready to start working.
Enable the control unit to run the device learning procedure. Refer to the control unit instruction manual for details.
Hold the Test button on the front cover pressed.
Refer to the instruction manual of the control unit to complete the learning process.
After having integrated the detector, set the control unit to "Walk Test" mode: keep the detector in the required position and
press the Test button to confirm that the concerned position is within the communication range of the control unit; see the
instruction manual of the control unit to complete the learning procedure.
Proceed with the installation after having ascertained that the detector is working in the desired position.
Installation
The detector was designed to be mounted on a flat surface or in a corner using the fixing screws and the anchor bolts
provided.
Hole arrangements are provided on the base where the plastic is thinner and may be broken for mounting. The two hole
arrangements are used to fix on a surface, while the four hole arrangements are used for fixing in a corner, as shown in the
following figure.
Surface mounting
I.
Remove the fixing screws and the cover.
II.
Perforate the appropriate hole arrangements on the inner side
of the base.
III. Using the template for the holes, make the holes in the surface.
IV. Insert the anchor bolts if the device is fixed to plaster or bricks.
V.
Screw the base into the anchor bolts.
VI. Screw the cover onto the base, making sure that the rubber of the tamper is well
pressed against the fixing surface
Corner mounting:
I.
Drill the arrangements for the holes on the triangular bracket.
II. Using a template for the holes, make the holes in the corner.
III. Insert the anchor bolts.
IV. Screw the triangular base onto the anchors, positioning it so that the hollow area
is facing you.
V. Hook the detector onto the triangular bracket.
<IMPORTANT NOTE>
With corner mounting it is not possible to guarantee the detection of the forced detachment from the wall.
Complete the installation
Choose the position of the detector, i.e. either in a corner or on a surface.
After having selected the installation position, follow the procedure described above to mount the detector.
DS1051-004