ENGLISH
Installation
height
LED
Transmitter LED (red)
The LED indicator blinks to indicate that signals are being transmitted in the following situations.
-
The Learn/Test button is pressed.
-
The tamper switch is actuated or reset.
-
Motion is detected in Test mode.
-
Motion is detected in flat battery or open tamper conditions during normal operation.
The LED does not blink if the tamper switch is closed, the battery is charged and the detector is not in Test mode.
The LED blinks to indicate signal transmission, blinking rapidly twice upon receiving confirmation from the panel.
The LED will blink every 4 seconds when the battery of the detector is flat.
Microwave detector LED (blue)
The LED lights up briefly when the microwave detector is in Test or in Microwave Test mode.
IR detection LED (green)
The LED lights up briefly when the microwave detector is in IR Test mode.
Jumper
Supervision Jumper. Not fitted, Supervision is always enabled.
Microwave test on/off jumper (JP3)
When the jumper is set to ON, the detector is in microwave Test mode (see Microwave test mode).
When the jumper is set to OFF, microwave Test mode is deactivated. (default)
Tamper switch
The detector is protected by a tamper switch which exits from the hole provided in the rear cover and is normally compressed against a
wall or an installation surface. The tamper alarm is activated when the detector is removed form the installation surface.
Microwave range trimmer
The range is indicated on the right, with the arrow pointing to the set sensitivity level:
-
Turned clockwise it increases the detection range (up to 20 metres)
-
Turned anticlockwise it decreases the detection range (to a minimum of 3-5 metres)
Default value: set to a medium value, approximately 10 metres.
-
Test mode
The detector can be set to Test mode by pressing the specific Learn/Test button. Test mode lasts for 3 minutes and restarts from 3
minutes whenever the Learn/Test button is pressed. In Test mode, the sleep timer is deactivated and the LEDs light up when the
detector detects a movement to notify the user. Use Test mode to determine the detection coverage of the detector during sensor
installation.
time that elapses between the transmission of a movement and the next transmission
SLEEP TIME
Microwave Test mode
The microwave test mode is used to test the microwave range only. Use the jumper JP3 to enable microwave test mode. When the
detector is in microwave test mode, PIR detection is deactivated, the microwave transmitter is activated to repeatedly send microwave
signals for detecting motion. When the detector detects motion in microwave Test mode, the blue microwave LED generates a signal by
lighting up for a short time.
4
Coverage diagram
Infrared range
1. Transmitter LED (red)
2. Microwave detector LED
(blue)
3. IR detection LED (green)
4. Learn/Test button
5. Lens
6. Battery housing
7. Supervision jumper
8. Microwave test on/off jumper
(JP3)
9. Tamper switch
10. Microwave range trimmer
11. Tamper hole
12. Pre-cut area
DS1051-037