Télécharger Imprimer la page

Kopp INFRAcontrol 3D 110 Mode D'emploi page 21

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Technische Daten
Rated voltage
Rated current
Closing current
Switching contact
Frequency
Standby power
Detection angle
No of levels
Detection range (20°C)
Rotation angle Sensor head
Recommended mounting high
Duty cycle
Twilight
Connection technology
Switching power
Standard bulbs
Halogen lamps
Fluorescent lamps
Inductive loads
LEB lamps
Optional RC-device
Environmental temperature
Storage temperature
Protection class
230 V~; +-10%
4 A
16 A (max. 0,4 Sec.)
Closing contact (µ Opening width)
50 Hz
< 1 W
110° (8237.0201.1; 8237.0501.4)
180° und 110° (8238.0201.4; 8238.0501.7)
1 (8237.0201.1; 8237.0501.4)
2 (8238.0201.4; 8238.0501.7)
12 m (8237.0201.1; 8237.0501.4)
3 m at 180° / 12 m at 110° (8238.0201.4; 8238.0501.7)
Vertical: +-15°; horizontal: +-35°
2,5 m
Continuously variable. Circa 5 sec. (T) - circa 12 min (+)
Continuously variable. Night (Moon) / Day (T)
3-wire (L, N, connection for consumer load)
max. 1500 W (ohmic Load)
max. 1500 W
max. 1500 W
max. 1000 W (In-Line compensation)
max. 400 VA
300 VA
100 nF / 100 Ω. Parallel to inductive load
-10 °C --> +50 °C
-20 °C --> +60 °C
IP 44
D
GB
NL
F
I
P
21