Setting the twilight threshold
Set the desired brightness value with the adjustment
screw (see illustration).
• Adjustment screw to the stop on the right side means:
D
night operation
• Adjustment screw to the stop on the left side means:
day operation
GB
Setting the duty cycle (switch-off delay)
• Set the desired duty cycle with the adjustment screw.
NL
• Adjustment screw to the stop on the right side means:
maximum duty cycle, approx. 720 seconds
• Adjustment screw to the stop on the left side means:
minimum duty cycle, approx. 5 seconds
F
• The listed duty cycles are approximate values and are
subject to technical deviations
Function test
I
Set the adjustment screw to „shortest duty cycle" and
twilight threshold to „day operation".
Pass through the detection range transversally.
P
The connected load, e.g. lamp should switch on.
After expiration of the set duty cycle, the lamp should
switch off again.
After a successful function test, set the desired parame-
ters (twilight threshold, duty cycle) for constant operati-
18
on. At least 10 seconds of rest between tests comply.
Switching examples
Basic wiring motion sensor ( Page 4 l 1 )
For resistive and inductive loads
Parallel motion sensor ( Page 4 l 2 )
• Several motion sensors can be switched parallel to one