9
• The unit should not be used where flammable gas, oxi-
gen or aerosol spray products are being used.
• Keep the air vents open.
• Do not place the unit on a soft surface where the ope-
nings can be blocked.
• If the water tank or medicine cup is empty, do not at-
tempt to operate the unit.
• If any abnormality occurs, discontinue use until the unit
has been examined and repaired.
• The unit should not be left unattended while plugged in.
• Do not use solution other than water in the tank. It may
damage the transducer.
• Do not tilt or shake the unit when in operation.
• Opening the top cover during operation may cause a
severe injury.
• Disconnect the unit from the electrical outlet before
cleaning, filling and after each use.
• Do not use attachments unless recommended by the
manufacturer.
• The unit should not be used for more than 20 minutes
at a time.
• Wait 30 minutes before reusing the unit.
Operating Caution
• Keep your eyes away from the output of medication
mist.
• Charge the water after each use.
• Dilute dense medications or medication volume 2 ml.
or less with distilled water or saline solution to obtain a
volume of at least 4 ml.
• Do not use this unit while operating a vehicle.
• If any discomfort or abnormality occurs, stop using the
unity immediately.
Storage Cautions
• Do not store the unit in direct sunlight, hight tempera-
ture or humidity.
• Keep the unit out of reach of small children.
• Always keep the unit unplugged while not in use.
Cleaning Cautions
• Check the medication cup, mouth nozzle and air filter before
each use. Dirty or worn parts should be replaced.
• Do not immerse the unit in water. It may damage the
unit.
• Disconnect the unit from the electrical outlet beforecle-
aning.
• Clean all necessary parts after each use as instructed
in this guidebook.

CLEANING PROCEDURE

It is important to clean your PINGOO Nebulizer before
the first time it is used and after each use.
Remember: Disconnect the unit from the electrical
outlet and never immerse the unit in the water.
Cleaning the parts:
The mouth nozzle, nose piece, extension tube, mask, top
cover, medicine, airflow cover, fan and air filter should
be cleaned with a mild detergent or commercially avai-
ble disinfectant. Thoroughly rinse each part and alow to
ENGLISH
competely air dry before using.
Cleaning the main unit:
The main unit should be cleaned with a soft cloth moiste-
ned with a non abrasive cleanser and water.

OPERATING YOUR NEBULIZER

Follow the previous cleaning instruction prior to usig
your PINGOO Ultrasonic Nebulizer for the first time or
after it has been stored for an exstended period.
Remember: Always disconnect the main unit from the
electrical outlet before cleaning and filing and after
each use.
To fill the water tank
1. Remove the top cover by pulling
straight up Fig.1. Remove the me-
dicine cup if applicable.
2. Select either tap or distillated wa-
ter* that has a temperature range
of 68ºF - 86ºF (20ºC-30ºC), Fig. 2
*Distilled water is preferred.
Fig. 1
3. Fill the water tank with tap or di-
stilled water to the indicated level
(between the 2 lines located insi-
de the water tank). Fig. 3
Remember: Do not use solution
68°F-86°F
other than water in the tank. It may
20°C-30°C
damage the tranducer - Fill to the
Fig. 2
correct level.
Note: The use of cool water (below
68ºF or 20ºC) will result in a lower rate
of nebulization. The use of warm water
(above 86ºF or 30ºC) will result in a hi-
Fig. 3
gher rate of nebulization.
To fill the medicine cup
1. Place the medicine cup inside the water tank.
2. Pour the medicine directly into the medicine cup.
3. Replace the top cover.
Remember:
• The maximum capacity of the medicine cup is 4.5
ml. and should not be overfilled.
• Dilute dense medications or medication volumes 2
ml. or less with distilled water or saline solution to
obtain a volume of at least 4 ml.
• Only use medications under the instructions of your
physician.
To connect the AC adapter
1. Insert the adapter plug into the unit's
AC port, Fig. 4.
2. Plug the adapter into a standard AC
outlet.
Fig. 4
To start the unit
1. Place the unit on a solid, flat, dry surface making sure
that the water tank and medicine cup have been pro-
perly filled and the mouth nozzle is properly attached
to the top cover.