Checking the Horizontal Levelling Accuracy of
the Longitudinal Axis
A free measuring distance of 20 m on a firm sur-
face between two walls A and B is required for
the check.
– Mount the measuring tool onto the holder or
a tripod, or place it on a firm and level sur-
face close to wall A. Switch the measuring
tool on.
A
20 m
– Direct the horizontal laser beam, which runs
parallel to the longitudinal axis of the meas-
uring tool, at the close wall A. Allow the
measuring tool to level in. Mark the centre of
the laser beam on the wall, (point I).
A
180˚
– Turn the measuring tool around by 180°,
allow it to level in and mark the centre point
of the laser beam on the opposite wall B
(point II).
Bosch Power Tools
– Without turning the measuring tool, position
it close to wall B. Switch the measuring tool
on and allow it to level in.
A
B
– Align the height of the measuring tool (using
the tripod or by underlaying, if required) in
such a manner that the centre point of the
laser beam is projected exactly against the
previously marked point II on wall B.
A
d
B
– Rotate the measuring tool by 180° without
changing the height. Allow it to level in and
mark the centre point of the laser beam on
wall A (point III). Take care that point III is as
vertical as possible above or below point I.
– The difference d of both marked points I and
III on wall A results in the actual height de-
viation of the measuring tool alongside the
Longitudinal axis.
On the measuring distance of 2 x 20 m = 40 m,
the maximum allowable deviation is:
40 m x ±0.3 mm/m = ±12 mm.
Thus, the difference d between points I and III
may not exceed 12 mm (max.).
www.geooptic.ru
English | 15
B
B
180˚
1 609 929 S07 | (2.10.08)