9.
Anti Tamper Alarm
The unit uses a LDR (light dependent resistor) as an anti tamper alarm.
If the keypad is removed from the cover then the tamper alarm will operate.
10.
Sound and Light indication
Operation Status
Power on
Stand by
Press keypad
Operation successful
Operation failed
Enter into programming mode
In the programming mode
Exit from the programming mode
Open the door
Alarm
11.
Detailed Programming Guide
11.1
User Settings
To enter the programming mode
*
Master code
999999 is the default factory master code
To exit from the programming mode
Note that to undertake the following programming the master user must be logged in
To change the master code
0
New code
#
The master code can be 6 to 8 digits long
Setting the working mode:
Set valid card only users
3
0
#
Entry is by card only
Set valid card and PIN users
Entry is by card and PIN together
3
1
#
Set valid card or PIN users
3
2
#
Entry is by either card or PIN (default)
To add a user in either card or PIN mode,
i.e. in the
3
Red Light
-
Bright
-
-
-
Bright
-
Bright
-
Bright
#
New code
#
2
#
mode. (Default setting)
Green Light
Yellow Light
Bright
-
-
Bright
-
-
-
Bright
-
Bright
-
*
7
User Manual
Buzzer
-
Di
-
-
-
Di
-
Di
-
DiDiDi
-
Di
-
Di
-
Di
-
Alarm
EN