4 Operation / 5 Memory
4.4
Switching off
the unit

5 Memory

5.1
Displaying
stored results
5.2
Deleting memory
20
5. When the measurement is finished, the cuff is deflated completely. The
systolic and diastolic blood pressure and the pulse value with the pulse
symbol
appear on the display
flashes next to the relevant coloured bar depending on the WHO blood
pressure classification (see page 16). The measured results will be an-
nounced in the language set if the language function is switched on.
6. The measured values are stored automatically. Up to 60 measured values
with date and time may be stored in the memory.
The unit has an automatic switch-off function. The unit switches off automati-
cally after a minute if no buttons are pressed.
The unit may also be switched off using the START button
The time and the date are constantly shown in the display.
The memory of your blood pressure monitor will hold up to 60 measurements
(blood pressure and pulse with time and date). The measured values are stored
automatically. Press the MEM button
The saved data will appear on the display. Initially the number of memory loca-
tions occupied will appear then the values of the most recently saved measu-
rement including the flashing blood pressure indicator
If the voice function has been activated, the device speaks the memory
location number, together with the saved blood pressure and pulse values and
the blood pressure assessment as per the scale in the World Health Organisa-
tion guidelines (see page 16).
Repeatedly pressing the MEM button
measured previously. In memory recall mode, the unit will switch off auto-
matically after approx. 120 seconds if the last entry has been reached and no
button is pressed. Memory recall mode can be exited at any time by pressing
the START button
, which will also switch the unit off.
If all 60 memory locations in the memory are occupied, a new measured value
is saved whilst the oldest value is deleted.
If you are in memory recall mode, press and hold the MEM button
approximately 8 seconds. All measured data stored will be deleted automati-
cally after three beeps. Only noughts will be shown on the display instead of
the measured values.
. The blood pressure indicator
.
to call up the saved measured values.
will be displayed.
displays the respective values
for