Cleaning The Condenser; Technical Specifications - Polar Refrigeration CM530 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Take care when cleaning the rear of the appliance. Sharp edges can cut.
A POLAR agent or qualified technician must carry out repairs if required.

Cleaning the Condenser

Periodically cleaning the condenser can extend the life of the appliance.
Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline or your POLAR dealer.
Fault
The appliance is
The unit is not switched on
not working
Plug and lead are damaged
Fuse in the plug has blown
Power supply
Internal wiring fault
The appliance
Too much ice on the evaporator
turns on, but the
Condenser blocked with dust
temperature is
Lid not shut properly
too high/low
Appliance is located near a heat source
or air flow to the condenser is being
interrupted
Ambient temperature is too high
Appliance is overloaded
The appliance is
The appliance is not properly levelled
leaking water
The appliance is
Loose nut/screw
unusually loud
The appliance has not been installed in
a level or stable position

Technical Specifications

Model
Voltage
Power Current
CM530
230V 50Hz
230W
CM531
230V 50Hz
270W
CM532
230V 50Hz
270W
CM433
230V 50Hz
200W
CM434
230V 50Hz
250W
CM530-CM532_CM433-CM434_ML_A5_v3_170427.indb 5
Probable Cause
Temperature
Capacity
Range
(litres)
2.5A
-24 to -18C
385
2.1A
-24 to -18C
516
2.4A
-24 to -18C
587
1.2A
-24 to -18C
200
1.2A
-24 to -18C
270
Solution
Check the unit is plugged in correctly and
switched on
Call POLAR agent or qualified Technician
Replace the fuse
Check power supply
Call POLAR agent or qualified Technician
Defrost the appliance
Clean the Condenser
Check lid is shut and seals are not damaged
Move the freezer to a more suitable location
Increase ventilation or move appliance to a
cooler position
Reduce the amount of food stored in the
appliance
Adjust the screw feet to level the appliance
(if applicable)
Check and tighten all nuts and screws
Check installation position and change if
necessary
Dimensions
Refrigerant
H x W x D mm
R600a 105g
845 x 1395 x 688
R600a 110g
845 x 1795 x 688
R290 100g
845 x 1995 x 688
R600a 75g
920 x 953 x 553
R290 80g
928 x 1195 x 654
UK
Weight
(kg)
67
82
87
42
60
5
2017/4/27 16:17

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cm531Cm532Cm433Cm434

Table des Matières