Connecting 4-Wire Connection: Power Supply Cord
A 4-wire connection is required for mobile
IMPORTANT:
homes and where local codes do not permit the use of
3-wire connections.
Standard Power Supply Cord Connectors
Flanged Spade Connector
Connecting Ground and Neutral Wires
1. Remove center terminal block screw (A) and neutral ground
wire (B) by removing the external ground conductor screw
(C).
B
2. Connect neutral ground wire (B) and neutral wire (white or
center wire) (D) of power supply cord under center terminal
block screw (A). Tighten screw.
D
Connecting 3-Wire Connection: Power Supply Cord
Standard Power Cord Connectors
Flanged Spade Connector
ELECTRIC DRYER ELECTRICAL CONNECTIONS
ELECTRIC DRYER ELECTRICAL CONNECTIONS
Ring Connector
A
C
B
A
Ring Connector
Connecting Power Cord Ground Wire
3. Connect ground wire (green or bare) (E) of power supply cord
under green external ground conductor screw (C). Tighten
screw.
E
Connecting Remaining Wires
4. Connect remaining wires with outer terminal block screws
(F). Tighten screws. Finally, reinstall terminal block cover to
dryer rear panel. Secure cover with hold-down screw. Now
go to "Venting Requirements."
Connecting Neutral Wire
1. Loosen or remove center terminal block screw (A).
C
F
F
A
19