Using the cooling unit
NOTICE!
A
Disconnect the cooling device and other power consuming devices
from the battery before you connect the battery to a quick charging
device. Overvoltage can damage the electronics of the device.
For safety reasons the cooling unit is equipped with an electronic system to
prevent polarity reversal. This protects the cooling unit when it is connected
to a battery.
Connecting to a 230 V mains supply
WARNING!
!
Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
If you are operating your cooling device on board a boat with
a mains connection of 230 V from the land, you must install
a residual current circuit breaker between the 230 V mains
supply and the cooling device.
Seek advice from a trained technician.
➤ To operate the cooling unit from the 230 V mains, use the WAECO
rectifier
– EPS-100W for devices with Bd-35F compressor (50/80/CS series),
– MPS-35 for devices with Bd-35F compressor (50/80/CS series),
– MPS-50 for devices with Bd-50F compressor (90 series).
NOTE
I
The output voltage of the described rectifier is 24 V. Please
remember this when connecting other consumers at a later time.
7
Using the cooling unit
7.1
Energy saving tips
Choose a well ventilated installation location which is protected from
direct sunlight.
Allow hot food to cool down first before placing it in the device.
Do not open the refrigerated container more often than necessary.
Do not leave the door open for longer than necessary.
Defrost the refrigerated container once a layer of ice forms.