Disposal
10
Disposal
➤ Place the packaging material in the appropriate recycling waste bins
wherever possible.
If you wish to finally dispose of the product, ask your local recycling
M
centre or specialist dealer for details about how to do this in
accordance with the applicable disposal regulations.
11
Troubleshooting
LED on the thermal element (fig. 1 2, page 3)
Number of
Error type
flashes
1
Battery protection shutdown
2
Fan overvoltage shutdown
3
Compressor start-up fault
4
Compressor overload shutdown
5
Electronic fuse shutdown
50
ColdMachine
Remedy
Check battery voltage, fuse and
cable cross section
Check condenser and vaporiser fan
current:
total target value < 0.5 A
Reduce load on cooling system:
– Ensure good ventilation around the
cooling unit
– Store pre-cooled goods
Reduce load on cooling system:
– Ensure good ventilation around the
cooling unit
– Store pre-cooled goods
Reduce load on cooling system:
– Ensure good ventilation around the
cooling unit
EN