1-4.1 DLP240/E
DC ON
H
V.ADJ
ALM
IND.CONT.EQ.
45JB
Made in China
BAR CODE
Input Details
100-240VAC 3.5A Maximum
Power Factor Corrected
Frequency : 50/60Hz
1
+V: +Output terminal
2
- V: - Output terminal
3
V.ADJ: Output voltage adjust trimmer
The output voltage rises when a trimmer is
turned clockwise.
4
L: AC Input terminal
Live line (fuse in line)
5
N: AC Input terminal
Neutral line
6
FG: Input terminal FG
Safety earth (Frame Ground)
Connect to safety ground of apparatus
or equipment.
+V
+V
-V
-V
Output Details
Continuous Loading 24VDC/10A
N
L
2. Terminal Connecting Method
Pay attention to the input wiring. If it is connected to
wrong terminal, the power supply will be damaged.
•
Input must be off when making connections.
•
Connect FG terminal of input connector and
mountable FG to ground terminal of the
equipment.
•
The output load line and input line shall be
separated and twisted to improve noise
sensitivity.
When connecting or removing input and output wire,
do not apply stress to PCB.
2-1.1 DLP75/E
+V
-V
V.ADJ
H
DC ON
ALM
BAR CODE
N
L
TDK-Lambda
DLP/E Series
INSTRUCTION MANUAL
IND.CONT.EQ.
45JB