TDK-Lambda DLP Série Mode D'emploi page 17

Table des Matières

Publicité

1-4.1 DLP240/E
DC ON
H
V.ADJ
ALM
IND.CONT.EQ.
45JB
Made in China
BAR CODE
Input Details
100-240VAC 3.5A Maximum
Power Factor Corrected
Frequency : 50/60Hz
1
+V: +Output terminal
2
- V: - Output terminal
3
V.ADJ: Output voltage adjust trimmer
The output voltage rises when a trimmer is
turned clockwise.
4
L: AC Input terminal
Live line (fuse in line)
5
N: AC Input terminal
Neutral line
6
FG: Input terminal FG
Safety earth (Frame Ground)
Connect to safety ground of apparatus
or equipment.
+V
+V
-V
-V
Output Details
Continuous Loading 24VDC/10A
N
L
2. Terminal Connecting Method
Pay attention to the input wiring. If it is connected to
wrong terminal, the power supply will be damaged.
Input must be off when making connections.
Connect FG terminal of input connector and
mountable FG to ground terminal of the
equipment.
The output load line and input line shall be
separated and twisted to improve noise
sensitivity.
When connecting or removing input and output wire,
do not apply stress to PCB.
2-1.1 DLP75/E
+V
-V
V.ADJ
H
DC ON
ALM
BAR CODE
N
L
TDK-Lambda
DLP/E Series
INSTRUCTION MANUAL
IND.CONT.EQ.
45JB

Publicité

Table des Matières
loading