The range hood is designed to remove smoke, cooking vapors
and odors from the cooktop area. For best results, start the hood
before cooking and allow it to operate several minutes after
the cooking is complete to clear all smoke and odors from the
kitchen.
The range hood controls are located on the front of the canopy.
A
B
D
A. Louver holes (non-vented
[recirculating] installations only)
B. Chimney covers
C. Lamps
Controls
Hi
Fan
Med
Fan
On-Off
Fan
Fan On-Off
Touch the "Fan On-Off" keypad to turn the fan on or off.
Med Fan
Touch the "Med Fan" keypad to turn the fan to medium speed.
Hi Fan
Touch the "Hi Fan" keypad once to turn the fan to high speed.
Touch the "Hi Fan" keypad twice to turn the fan to the highest
fan speed.
NOTE: The highest fan speed lasts for approximately 5 minutes,
then the fan returns to the high fan speed automatically.
RANGE HOOD USE
F
E
C
D. Filter door
E. Canopy
F. Control panel
Timed
Quiet
Light
Fan
Fan
On-Off
Timed Fan
Touch the "Timed Fan" keypad to set the automatic shutdown
timer.
Set automatic shutdown timer:
Press one of the following keypads to set the automatic
shutdown of the fan according to desired shutdown time:
1. Quiet Fan: 20 minutes
2. Med Fan: 15 minutes
3. Hi Fan: 10 minutes
When the "Timed Fan" keypad flashes, maintenance of the
charcoal filter needs to be completed. Once completed, touch
and hold down the "Fan On-Off" keypad until the flashing stops.
Quiet Fan
Touch the "Quiet Fan" keypad to select the 'silent' fan. This fan
speed provides a subtle fan speed.
When the "Quiet Fan" keypad flashes, maintenance of the
grease filter needs to be completed. Once completed, touch and
hold down the "Fan On-Off" keypad until the flashing stops.
Light On-Off
Touch the "Light On-Off" keypad to turn the hood light on or off.
Automatic operation under high temperature
conditions
The hood is equipped with a sensor which detects the
cooking temperature. When this becomes too high, the sensor
automatically turns on the medium fan speed. The hood turns off
once the temperature has cooled down.
When the "Med Fan", "Hi Fan" and "Timed Fan" keypads flash,
the automatic sensor will turn on.
Activation of the charcoal filter maintenance indicator
This indicator is automatically set to Off. To activate it, proceed
as follows:
With the hood off, press and hold the "Med Fan" and "Hi Fan"
keypads at the same time until both keypads flash.
Deactivation of charcoal filter maintenance indicator
With the hood off, press and hold the "Med Fan" and "Hi Fan"
keypads at the same time until both keypads flash. This is
followed by flashing only "Hi Fan" keypad to indicate successful
deactivation.
15