preparing the boiler for operation

Addressing the system interface

1) Find menu 0 "Network" then confi rm with the OK key. Select sub-
menu 03 "Interface system" then confi rm with the OK key.
2) Select sub-menu 030 "Zone number" then confi rm with the OK
key and assign a confi guration code to the system interface :
- 0 no setting zone (Systeme interface not assigned to any zone)
- 1 zone 1 setting (Systeme interface assigned to heating zone 1)
- 2 zone 2 setting (Systeme interface assigned to heating zone 2)
- 2 zone 3 setting (Systeme interface assigned to heating zone 3)
then confi rm with the OK key.
3) Carry out the same operation on each the system interface
(if necessary).
4) Return to the main display by repeatedly pressing the
At this stage, the module is operational with the factory parameters.
Possible confi gurations (see below).

Confi guration of the temperature control by zones

Zone 1
System interface
* The system interface is connected to
the module BUS BridgeNet®.
* Assign confi guration code "1" to para-
meter 030 on the system interface.
Room sensor
* The room sensor is connected to the
module BUS BridgeNet®.
* Refer to the room sensor instructions
to assign it to Zone 1.
Weekly room thermostat
* The weekly room thermostat is connec-
ted to the "TA1" terminal block on the
module.
key
Zone 2
System interface
* The system interface is connected to
the module BUS BridgeNet®.
* Assign confi guration code "2" to para-
meter 030 on the system interface.
Room sensor
* The room sensor is connected to the
module BUS BridgeNet®.
* Refer to the room sensor instructions
to assign it to Zone 2.
Weekly room thermostat
* The weekly room thermostat is connec-
ted to the "TA2" terminal block on the
module.
Zone 3
System interface
* The system interface is connected to
the module BUS BridgeNet®.
* Assign confi guration code "3" to para-
meter 030 on the system interface.
Room sensor
* The room sensor is connected to the
module BUS BridgeNet®.
* Refer to the room sensor instructions
to assign it to Zone 3.
Weekly room thermostat
* The weekly room thermostat is connec-
ted to the "TA3" terminal block on the
module.