Technical Data; Accessories; Warranty - hawa 2451 Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

b) Exchange of the attachment screw in the lid
Unscrew the securing nut DIN 985, M5 until the nut is flush to the lid edge.

8. Technical Data

Static loads:
Maximum load, incl. weight of enclosure:
Maximum load on mounting plate:
Maximum load on lids:
Notes:
All specifications apply:
a) provided the load is evenly distributed on the surface or in the space,
b) for attachment according to the specified position when in use – see Instructions for Installation.
IK rating: IK08 (if used in compliance with its intended use).
IP rating: IP66/69
Torque specifications:
The specifications stated below have been uniquely determined for standard stainless-steel enclosures and are deemed to be binding
under optimum conditions.
Mounting plate:
Attachment of mounting plate:
Stainless steel: 1.5 Nm
Lock (also after exchange and repair:)
Stainless steel: 1.0 Nm
Caution: This value is an average and may vary by ±0.2 Nm in individual cases. See photos chapter 6 internal fitting.
Protective conductor:
Attachment of grounding cable / grounding straps to ground stud:
Stainless steel: 4 Nm
All technical details have been uniquely determined for products type 2451.

9. Accessories

Protective conductor symbol label (1 set = 100 pieces): 3080-9102-13-12
Cable for protective conductor connection (1 set = 5 cables with mounting hardware)
Length = 180 mm: 3080-9036-05-18
Length = 300 mm: 3080-9036-05-28
Further accessories available upon request.

10. Warranty

These instructions are subject to our General Terms and Conditions: http://www.haewa.com/company/imprint.html.
We do not accept liability for printing errors.
Up to W x L in mm:
200 x 200
300 x 300
exceeding dim.
200 N
300N
500 N
400 N
150 N
14