b) Exchange of the attachment screw in the lid
Unscrew the securing nut DIN 985, M5 until the nut is flush to the lid edge.
8. Technical Data
Static loads:
Maximum load, incl. weight of enclosure:
Maximum load on mounting plate:
Maximum load on lids:
Notes:
All specifications apply:
a) provided the load is evenly distributed on the surface or in the space,
b) for attachment according to the specified position when in use – see Instructions for Installation.
IK rating: IK08 (if used in compliance with its intended use).
IP rating: IP66/69
Torque specifications:
The specifications stated below have been uniquely determined for standard stainless-steel enclosures and are deemed to be binding
under optimum conditions.
•
Mounting plate:
Attachment of mounting plate:
Stainless steel: 1.5 Nm
•
Lock (also after exchange and repair:)
Stainless steel: 1.0 Nm
Caution: This value is an average and may vary by ±0.2 Nm in individual cases. See photos chapter 6 internal fitting.
•
Protective conductor:
Attachment of grounding cable / grounding straps to ground stud:
Stainless steel: 4 Nm
All technical details have been uniquely determined for products type 2451.
9. Accessories
•
Protective conductor symbol label (1 set = 100 pieces): 3080-9102-13-12
•
Cable for protective conductor connection (1 set = 5 cables with mounting hardware)
Length = 180 mm: 3080-9036-05-18
Length = 300 mm: 3080-9036-05-28
Further accessories available upon request.
10. Warranty
These instructions are subject to our General Terms and Conditions: http://www.haewa.com/company/imprint.html.
We do not accept liability for printing errors.
Up to W x L in mm:
200 x 200
300 x 300
exceeding dim.
200 N
300N
500 N
400 N
150 N
14