Instructions For Transport; Instructions For Installation And (Interior) Fittings - hawa 2451 Notice De Montage Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Instructions for Transport

The product must be transported in an upright position – preferably on a pallet. When transported individually without interior fittings (except profile
rail or mounting plate at the rear panel) and with no load on the lid,
the enclosure can also be moved lying flat on the back. During transport, the product must be suitably secured against tipping over (attention must be
paid to load distribution, center of gravity).
In curves, the enclosure must be moved slowly, independent of the means of transport. A tip-over hazard exists for tall or top-heavy empty enclosures.
Use straps or transport belts so as to avoid point loads on the lid. There is the danger of damaging the hygiene seal.
Pay attention to a clean working environment to avoid slipping and/or falling.
Use appropriate protective equipment (e.g. gloves, safety shoes).
Enclosures must always be transported or lifted on a pallet.
Secure fitted mounting plates through additional measures, if necessary.

6. Instructions for Installation and (Interior) Fittings

Installation
During unpacking and installation, suitable measures must be taken to secure the product against tipping over (attention must be
paid to load distribution, center of gravity).
Check the product for completeness – see Scope of Delivery.
Prior to installation, check the product for any damage.
Pay attention to a clean working environment to avoid slipping and/or falling.
Use appropriate protective equipment (e.g. gloves, safety shoes).
Operating position: mounted or welded to a wall or to a mounting frame, roof pitch towards the non-food zone (DIN EN 1672-2, 5.3.3).
Horizontal and torsion-free installation is a requirement for maintaining the IP degree of protection.
Pay attention to the maximum loads applicable to the installation options (position when in use) – see Technical Data.)!
Hygiene
Do not damage the surface or the seal during unpacking and installation.
Do not attach the rear panel directly to a mounting plane.
Deburr the necessary attachment holes.
Any welding work during on-site installation must be performed to professional and hygiene standards with regard to the welding technique
chosen and the materials used. Ensure that the body does not warp through heat ingress!
Notice: No warranty if warping through heat occurs.
Please pay attention to the alignment of inclined surfaces which must point away from sensitive areas.
When choosing the installation location on the machinery, take the following into consideration:
- space requirements for operation and maintenance works;
- space requirements for the maintenance of the empty enclosure;
- space requirements for the cleaning of the empty enclosure and adjacent areas.
(Interior) Fittings
Existing openings or drill holes or those made on-site must be properly closed with devices or other fittings that are at
least of the same IP protection rating as the empty enclosure.
Prior to putting the empty enclosure into service, the mechanical functions must be checked, in particular if the lid screws are tighten properly. Carry out a
visual inspection of the seals which are relevant for the maintaining of the protection degree as well as of the protective conductor.
Observe the torque values to ensure a gap-free sealing of the lid gasket to the body – see Technical Data.
Desired condition when lid is mounted