The D750M panel features an electronic photocell control system which switches the external
photocell transmitter on and off thereby causing the control unit microprocessor to check whether
the relay switches correctly. If this does not happen, the control unit is automatically blocked
•
MICROPROCESSOR-CONTROLLED LOGIC
•
SELF-DIAGNOSIS LED's
•
LINE INPUT FUSE
•
BUILT-IN TORQUE LIMITING DEVICE
•
ELECTRONIC CONTROL OF SAFETY DEVICES
•
PEDESTRIAN ENTRY FUNCTION
•
BUILT-IN FLASHING LIGHT CIRCUIT
•
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
•
"SLOW-DOWN" FUNCTION IN OPENING AND IN CLOSING PHASE
When all connections have been made:
All the green LS LED's must be on (each corresponds to a Normally Closed input).
They only turn off when the commands they are associated with are active.
All the red LS LED's must be off (each corresponds to a Normally Open input) they only turn on
when the commands they are associated with are active.
Power input to board
Max motors nominal power
Primary input line rapid fuse (F1 - 5x20)
Input voltage of motor circuits
Input voltage of auxiliary circuits
24Vac line rapid fuse (F2 - 5x20)
Logic circuit input voltage
Working temperature
Box protected to
DL1
OPEN/CLOSE button red LED signal
DL2
PEDESTRIAN button red LED signal
DL3
STOP button green LED signal
DL4
SENSITIVE EDGE green LED signal
DL5
INTERNAL PHOTOCELL green LED signal
DL6
EXTERNAL PHOTOCELL green LED signal
DL7
RADIO CONTROLS programming red LED signal
14
CONTROL CARD FOR TWO SINGLE-PHASE MOTORS 230 Vac
TECHNICAL CHARACTERISTICS
D750M
English
TESTING
230Vac - 50Hz
600 W ca.
F 6,3 A
230 Vac
24 Vac
F 1,6 A
5 Vdc
-20°C ÷ + 70 °C
IP43
DIAGNOSTICS LED